Text from PDF Page: 017

Capstone Turbine Corporation  21211 Nordhoff Street  Chatsworth  CA 91311  USA Technical Reference: Capstone C65 Electrical Table 6. Connector J8 – Inter-Controller (B) RS-485 Port Pin Signal Parameter J8 (A) J8 (B) J8 (C) J8 (D) J8 (E) J8 (F) J8 (G) J8 (H) J8 (J) J8 (K) J8 (L) J8 (M) Table 6 Notes: Serial Communication (Not Applicable) Inter-Controller Start (Not Applicable) Global E-Stop (Not Applicable) (Not Applicable) Global E-Stop Return (Not Applicable) Inter-Controller Start Return (Not Applicable) Serial Communication RS-485, Bus A Protocol (1) Chassis Ground +24 Volts DC @ 15 milliamps per microturbine (2) Chassis Ground Normal operation: N*42 milliamps. E-Stop: (+) 24 VDC (2) Chassis Ground Spare Normal operation: N*42 milliamps. E-Stop: 0 VDC Reserved 30 milliamps per microturbine @ 0 VDC Reserved RS-485, Bus B Protocol (1) Whenever J8 is at the extremities of the RS-485 multi-drop network; Capstone-provided terminators must be installed. The maximum number of nodes is 32, and the maximum RS-485 cable length is 1000 meters. Each microturbine has 1.93 meters of internal cable length, which must be included in the total length considerations. Repeaters may be added whenever the maximum cable lengths or the maximum numbers of nodes are exceeded. (2) The Global E-Stop connection sinks 42 milliamps per microturbine in a MultiPac E-Stop circuit. The voltage drop to the most remote microturbine in the interconnecting cables must be kept to 6 volts DC maximum N30 on any global E-Stop. 5.2. Serial Communication Ports (J3 and J5) A PC or PLC device may be connected to the UCB for monitoring, controlling, or trouble- shooting a microturbine system. The microturbine communicates via RS-232 protocols using a null modem cable with hardware handshaking. A DB9 connector (User Port) and a DB25 connector (Maintenance Port) are available. If devices are connected to both ports, the port accessed at a higher password level has priority for command of the system. If both are at the same password level, the Maintenance Port has priority. 5.2.1. DB25 Connector J3 (Maintenance Port) Table 7 and Figure 4 define the connections for connector J3. Table 7. DB25 Connector J3 (Maintenance Port) DB25 (male polarity) and RS-232 protocol. Maximum J3 Maintenance Interface Port null modem cable length is 50 feet (1) Table 7 Notes: (1) Connections made to these ports MUST be isolated from ground and/or communication ports of other microturbines. A 25-pin RS-232 connector is used for Maintenance Port and is identified as J3 on the C65 UCB (see Figure 4). Pin designations are as follows: 410001 Rev N (August 2013) Page 17 of 43 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction. Pin Signal Parameter

PDF Image | Technical Reference Capstone Model C65 Electrical

technical-reference-capstone-model-c65-electrical-017

PDF Search Title:

Technical Reference Capstone Model C65 Electrical

Original File Name Searched:

410001N_TR_C65_ELECTRICAL.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP