Text from PDF Page: 014
Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Advanced Power Server (APS): User’s Manual Window Name Open Method APS Version When in Configuration mode, double click the “APS Version/Log” option in the left side of Advanced Power Server Configure window. SA Group Meter Config When in Configuration mode, double click “Group/Turbine Setup” in the left side of the Advanced Power Server Configure window, then highlight (single click) “Standalone Groups” and select the “Edit Meter Config” option from the top drop-down menu in the middle of the Advanced Power Server Configure window. GC Group Meter Config When in Configuration mode, double click “Group/Turbine Setup” in the left side of the Advanced Power Server Configure window, then highlight (single click) “Grid Connect Groups” and select the “Edit Meter Config” option from the top drop-down menu in the middle of the Advanced Power Server Configure window. Group Dispatch Config #X When in Configuration mode, double click “Group/Turbine Setup” in the left side of the Advanced Power Server Configure window, then highlight (single click) one of the four groups that you want to setup and select the “Edit Group Dispatch Config” option from the top drop-down menu in the middle of the Advanced Power Server Configure window. Battery Management Settings, Frame X When in Configuration mode, double click “Group/Turbine Setup” in the left side of Advanced Power Server Configure window, then highlight (single click) one of the four groups that you want to setup and select the “Edit Group Turbine Config” option from the top drop-down menu in the middle of the Advanced Power Server Configure. Once this is done the top menu will change and you can then select the “Battery Management” option from the same drop-down menu GC Protective Relay Control Panel, Frame X When in Configuration mode, double click “Group/Turbine Setup” in the left side of Advanced Power Server Configure window, then highlight (single click) one of the four groups that you want to setup and select the “Edit Group Turbine Config” option from the top drop-down menu (in the middle of the Advanced Power Server Configure window). Once this is done, the top menu will change and you can then select the “GC Protective Relay” option from the same drop-down menu. SA Volt & Freq Control Panel, Frame X When in Configuration mode, double click “Group/Turbine Setup” in the left side of Advanced Power Server Configure window, then highlight (single click) one of the four groups that you want to setup and select the “Edit Group Turbine Config” option from the top drop-down menu (in the middle of the Advanced Power Server Configure window). Once this is done, the top menu will change and you can then select the “SA Volt & Freq Settings” option from the same drop-down menu. Fast Transfer Control, Frame X When in Configuration mode, double click “Group/Turbine Setup” in the left side of Advanced Power Server Configure window, then highlight (single click) one of the four groups that you want to setup and select the “Edit Group Turbine Config” option from the top drop-down menu in the middle of the Advanced Power Server Configure window. Once this is done, the top menu will change and you can then select the “Fast Transfer Settings” option from the same drop-down menu. Modbus Slave Register Map Master Data I/O 400011 Rev A (June 2007) When in Configuration mode, double click “Slave Register Map” in the left side of Advanced Power Server Configure window. When in Configuration mode, double click “Master Data I/O” in the left side of Advanced Power Server Configure window. Page 14 of 67 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | ADVANCED POWER SERVER (APS) USER’S MANUAL
PDF Search Title:
ADVANCED POWER SERVER (APS) USER’S MANUALOriginal File Name Searched:
400011_APS_Users_Manual.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP |