PDF Publication Title:
Text from PDF Page: 001
Capstone Capstone Turbine Corporation 21211 Nordhoff Street Chatsworth CA 91311 USA Telephone: (818) 734-5300 Fax: (818) 734-5320 Web: www.capstoneturbine.com Service Bulletin SB0106 Date: From: Subject: February 2011 Capstone Technical Support C1000 Engine Air Inlet Filter Retrofit Systems Affected Capstone C1000 Series systems (including C600/C800/C1000) with serial number listed in Table 1. Summary Capstone has introduced the C1000 Air Filter Deflector Plate, part number 529330-001, as a reliability improvement to improve the seal around the engine air inlet filter thus eliminating a potential source of foreign object damage (FOD) to the engine. Required Action If the serial number of your system is listed in Table 1, then the engine air inlet filter box must be field-retrofitted on all populated bays of your system. Table 1. Affected System Serial Numbers 55xx 56xx 57xx 5269 5346 5412 5413 5518 5680 5704 5438 5525 5681 5705 5439 5579 5706 5480 5580 5707 5498 5592 5708 58xx 59xx 60xx 5894 5985 6009 5990 6011 6012 6047 6061 6076 52xx 53xx 54xx 5516 5655 5703 5499 5737 5738 5739 5775 5780 If it is determined that your system requires this upgrade, refer to the C1000 Engine Air Inlet Filter Retrofit Work Instructions (440285) to perform the required retrofit. 450107 Rev A (February 2011) Page 1 of 2 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction. Copy is uncontrolled; user is responsible for verifying current revision.PDF Image | C1000 Engine Air Inlet Filter Retrofit
PDF Search Title:
C1000 Engine Air Inlet Filter RetrofitOriginal File Name Searched:
SB0106_C1000_Engine_Air_Inlet_Filter_Retrofit.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP |