PDF Publication Title:
Text from PDF Page: 007
Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Model C60/C65 Integrated CHP System (ICHP) Dual Mode Considerations In dual mode, any of the three CHP modes are allowed. No configuration changes will take place if the CHP is set to run in Thermal Bypass or Electrical Priority modes and the system automatically switches from Grid Connect to Stand Alone (or visa-versa). However, if the CHP is configured to work in Thermal Priority and the loss of grid is detected, the following sequence of events will occur: 1. The entire MultiPac will shut down and restart in Stand Alone mode. 2. CHP mode will switch to Electrical Priority to continue heat recovery. 3. No changes will be made to the setpoint and temperature feedback settings. While in Stand Alone, upon detecting the grid: 1. The entire MultiPac will shut down and restart in Grid Connect mode. 2. CHP mode will switch to Thermal Priority. 3. No changes will be made to the setpoint and temperature feedback settings. 410043 Rev. G (February 2006) Page 7 of 24 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Technical Reference Model C60/C65Integrated CHP System (ICHP)
PDF Search Title:
Technical Reference Model C60/C65Integrated CHP System (ICHP)Original File Name Searched:
410043_ICHP_Tech_Ref.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
| CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP |