Text from PDF Page: 053

Capstone Turbine Corporation Model C200 User’s Manual 4.7.8. Fast Transfer Delay Submenu Stand Alone 3/4 Fast Trans DLY 8/10 0.0 Min The Fast Transfer Delay submenu applies only to Dual Mode configured systems. This submenu displays the delay timer for the mode transition from Grid Connect to Stand Alone during fast transfer. The Initial Factory Setting is 0 minutes. The timer can be set from 0 to 30 minutes. The system will operate in Hot Standby while this timer runs before the transfer is completed. 4.7.9. Stand Alone Load Wait Submenu The Stand Alone Load Wait submenu applies only to Dual Mode configured systems. This submenu displays the timer that maintains the system in Stand Alone Load State before the transition back to Grid Connect, after the grid has returned to normal. The timer begins when the utility voltage and frequency are detected to be within the required operating range, and maintains the turbine in the Stand Alone load state until the time has expired. The Initial Factory Setting is 5 minutes. The timer can be set from 5 to 30 minutes. 4.7.10. Local Battery Charge Submenu The Local Battery Charge submenu controls whether the system begins a battery equalization charge. This can be done when the system is in Grid Connect mode, or in standby or Hot Standby state. Selecting ENABLE will begin the equalization charge, which can last up to 4 hours. The user must be logged in with the current password to change this setting. Stand Alone 3/4 SA Load Wait 9/10 5.0 Min Stand Alone 3/4 Local Batt Chg 10/10 DISABLE 400008 Rev G (October 2013) Page 53 of 64 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Capstone MicroTurbine Model C200 User's Manual

capstone-microturbine-model-c200-users-manual-053

PDF Search Title:

Capstone MicroTurbine Model C200 User's Manual

Original File Name Searched:

400008G_UM_C200_IND_PKG.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP