Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Component Descriptions - Model 330 MicroTurbine ‰ Interrupted when reboot operation performed ‰ Not powered if Emergency Stop is present ‰ Verify operation when LED D23 is illuminated ‰ Troubleshoot by checking for short in dump valve or engine harness. 4. Spark Exciter Power (U45) ‰ Power by 13.8V Switched Power ‰ Connector J1 pin C7 and D10 (Gnd) ‰ Supplied to Exciter Module in Package ‰ Enabled during Engine liftoff and low power operation of liquid fuel system. ‰ Interrupted when reboot operation performed ‰ Not powered if Emergency Stop is present ‰ Verify operation when LED D37 is illuminated ‰ Troubleshoot by checking for short in exciter module or engine harness 5. Intra A Power (U44) ‰ Power by 13.8V Switched Power ‰ Connector J3 pin A1/A4 and B1/B4 (Gnd) ‰ Provides switched power to all subsystem components connected to the Intra Controller Harness ‰ Enabled during engine operation. ‰ Interrupted when reboot operation performed ‰ Not powered if Emergency Stop is present ‰ Verify operation when LED D36 is illuminated ‰ Troubleshoot by checking for short in J3 harness and in RFC controller 6. Intra B Power (U43) ‰ Power by 13.8V Power ‰ Connector J3 pin A3 and B3 (Gnd) ‰ Provides logic power to all subsystem components connected to the Intra Controller Harness ‰ Enabled shortly after Modem Power on power up ‰ Interrupted when reboot operation performed ‰ Powered regardless of Emergency Stop status ‰ Verify operation when LED D35 is illuminated o Troubleshootbydisconnectingeachsubcomponenttocheckforashort condition. 410012-001 Rev A (Apr 2002) Page 34 of 44 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the equipment specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Technical Reference Component Descriptions Capstone Model 330 MicroTurbine

technical-reference-component-descriptions-capstone-model-33-034

PDF Search Title:

Technical Reference Component Descriptions Capstone Model 330 MicroTurbine

Original File Name Searched:

ComponentDescriptions_410012.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP