Text from PDF Page: 001

1030 Clarke Side Road • Box 5395 • Station B • London, ON Canada N6A 4P4 unifin@kochind.com SERVICE BULLETIN 8 DATE: April 9, 2003 R0 TO: micoGenTM Heat Recovery Unit Users Contact: Tim Ryan, Customer Service Leader RE: Excessive Heat Recovery From: L. Brescacin, Manager, Engineering & Product Development PHONE: (519) 451-0310 Ext 222 EMAIL: RyanT@Kochind.com FAX: (519) 451-0310 This bulletin is applicable only to second-generation micoGenTM units. In some cases the unit may be installed in an application for which it is oversized. In this case the unit will recover more heat than the utilization loop can absorb. When this occurs the circulating water temperature to and from the micoGenTM unit will continue to rise until the outlet set-point temperature is reached. Then the controller will move the diverter to bypass. If the amount of excess heat being recovered causes the actuator to cycle more than 5 times per hour it exceeds the equipment warranty limit. If actuator cycling is excessive, contact the service representative. Actuator cycling caused by excessive heat recovery can be remedied by allowing some of the exhaust gas to bypass the heat exchanger of the micoGenTM unit. To do so an experienced service representative can adjust the turnbuckle that controls the positioning of the diverter door. The adjustment must be finely monitored so that the amount of bypass does not cause under performance of the system. Even very small amounts of bypass can reduce performance very significantly. This modification of the diverter door setting can be done without harm to the micoGenTM unit. However, Unifin does not take responsibility for the resulting heat recovery due to this adjustment. Also, a tag must be attached to the actuator assembly to notify others that the actuator mechanism has been adjusted to permit bypass and note how much adjustment has been made. . Note: Second Generation micoGenTM serial numbers begin the number 4 or 5.

PDF Image | UNIGIN Service Bulletin 8 heat recovery unit users

unigin-service-bulletin-8-heat-recovery-unit-users-001

PDF Search Title:

UNIGIN Service Bulletin 8 heat recovery unit users

Original File Name Searched:

UnifinSB8.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP