Text from PDF Page: 001

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Telephone: (818) 734-5300 • Fax: (818) 734-5320 • Web: www.capstoneturbine.com Service Bulletin SB0118 Date: From: Subject: September 2013 Capstone Technical Support C1000 Series Systems Desiccant Replacement Systems Affected All C1000 Series (C600/C800/C1000) systems listed in Table 1. Summary Capstone has modified desiccant kits for C1000 series systems to better maintain humidity levels within engines and systems in storage. Original desiccant packages have been modified to eliminate the clay desiccant pack. All desiccant material has been changed to silica gel, and the quantity of silica gel desiccant packs has been doubled from four to eight. The purpose of the change is to better maintain humidity levels within engines and systems in storage. C1000 series systems in storage or installed and not yet commissioned (less than 12 months from date of shipment) require immediate change to the new desiccant kits. Refer to Table 1 for affected serial numbers. Required Action The following action is required to maintain warranty/FPP coverage: • Install desiccant kit(s) into affected system(s) (refer to Table 1) immediately. Refer to Capstone Model C200 Microturbine and C1000 Series Desiccant Kit Replacement Work Instructions (440297) for specific installation instructions. Responsibility It is Capstone’s responsibility to: • Provide this Service Bulletin containing description of the problem and a recommended solution to Capstone's Authorized Service Providers. • Make available the desiccant kit (530020-101) at no charge to Authorized Service Providers for the resolution of issues or enhanced functionality related to microturbine systems in storage. • For system under warranty or FPP:  If applicable, provide reimbursement for flat rate labor of o 3hoursforunpacking/repacking(requires2people,1.5hoursperperson) o 0.25hoursperbayfordesiccantreplacement 450126 Rev A (September 2013) Page 1 of 3 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction. Copy is uncontrolled; user is responsible for verifying current revision.

PDF Image | C1000 Series Systems Desiccant Replacement

c1000-series-systems-desiccant-replacement-001

PDF Search Title:

C1000 Series Systems Desiccant Replacement

Original File Name Searched:

SB0118_C1000_Desiccant_Change.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP