Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Work Instructions: Igniter Replacement – Model C60 MicroTurbine Required Tools 􏰪 10mm Socket for package removal 􏰪 3⁄4” Wrench 􏰪 #2 Phillips head screwdriver 􏰪 Flat head screwdriver 􏰪 12 point 1⁄4” Socket, Extension and Drive 􏰪 1⁄4” Torque Drive set to 45 in-lbs 􏰪 LPS Penetrating Compound 􏰪 Nickel-based Anti-Seize Compound Procedures 1. Shut down the engine and wait for cooldown for approximately three hours. 2. Remove all power sources and fuel supply from the MicroTurbine system. 3. Remove the MicroTurbine right side panel. 4. Disconnect igniter cable from spark exciter solenoid using the 3⁄4” wrench. 5. Spray the Igniter bolts with penetrating compound. Wait for five minutes. 6. Spray the Igniter bolts with penetrating compound again. Wait for five minutes. 7. Remove the igniter cable holding straps using the # 2 Phillips screwdriver and 5/16” flat head screwdriver. 8. Use the 12-point 1⁄4” socket and drive to remove the four igniter bolts. IMPORTANT: If any resistance is felt while removing the bolts DO NOT PROCEED! Spray more penetrating compound and wait. Due to the thermal expansion in this region, removal of the igniter bolts can be difficult. 9. Replace the igniter making sure to re-install the gasket. 10. Do not re-use the bolts! 11. Apply nickel-based Anti-seize compound to the threads of the new igniter bolts 12. Insert bolts and tighten using fingers. 13. Use the 45 in-lb torque drive to tighten the bolts. DO NOT over tighten. 14. Lead the igniter cable back through the connector in the frame to the exciter box. 15. Reconnect the igniter cable to the spark exciter solenoid. 16. Tighten by hand. 17. Use the 3⁄4” wrench to tighten. 18. Turn on power. 19. Turn on the fuel supply. 20. Test the system for proper operation as detailed in the MicroTurbine User’s Manual. 440029-001 Rev A (December 2002) Page 2 of 4 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Work Instructions Igniter Replacement Capstone Model C60 MicroTurbine

work-instructions-igniter-replacement-capstone-model-c60-mic-002

PDF Search Title:

Work Instructions Igniter Replacement Capstone Model C60 MicroTurbine

Original File Name Searched:

440029_Ignitor.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP