Text from PDF Page: 003

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Work Instructions: SPV to Woodward Valve Retrofit Kit Installation Material Information The following parts comprise the Woodward Valve Retrofit Kit 610098-100. Part Number 519347-100 519348-100 519480-001 518908-002 519345-100 519338-001 519346-100 519337-001 519344-100 519341-001 519342-001 519343-001 512294-010 519472-001 519471-001 514037-063 507750-001 507874-001 508430-013 514928-001 516993-100 518875-100 507274-002 506711-001 508106-001 514016-001 510622-002 510622-003 513808-001 513532-008 513532-012 513531-008 513531-012 Nomenclature UFCB Controller Assembly, Natural Gas Woodward Valve Assembly, Natural Gas Pressure Transducer Filter, 12, In-line, Flareless Tube Fitting Tube Assembly, -8 Woodward Valve Out-Manifold Tube, -12, Shutoff to Woodward Valve Inlet Tube Assembly, -6, Fuel Vent Out Tube, -12, Inlet to Shutoff Shutoff Assembly with Bracket Bracket, Shutoff, Woodward Valve Bracket, Shutoff, Inlet Tube Bracket, Anti-rotation Fitting, Bulkhead, -12 Tube x 1/2” NPT Male Fitting, Male Connector, -12 Tube to –12 Tube, NPT Fitting, Male Adapter, -12 Tube to –12 NPT, M, SS Bolt, Hex Head, M6 x 16, Zinc Washer, Flat 1/4-inch, 1/16 thickness, 1/2 OD Washer, Split-lock, 1/4 zinc-plated Nut, Hex, KEPS, Ext-lock washer Fitting, Bulkhead, -6 Tube to 1/4 NPT CABA, C200, FCM Fuel Valve CABA, Ext C60 UFCB to Manifold Sealant, Pipe Tape, Natural Gas Locker, Thread (Locktite 242) Washer, Flat, 1-inch (1.062 ID, 2.5 OD), Zinc Label, High Pressure, NG Seal, 37°, Conical –8, Crush Washer, NI Seal, 37°, Conical –6, Crush Washer, NI Filter, Vent, 1⁄4 NPT, 4 cfm Nut, Tube, BZ, -8, CPI Ftg, SS Nut, Tube, BZ, -12, CPI Ftg, SS Ferrule, Tube, TZ, -8, CPI Ftg, SS Ferrule, Tube, TZ, -12, CPI Ftg, SS Qty 1 1 1 1 1 1 1 1 2 1 1 1 1 3 1 16 16 8 8 1 1 1 A/R A/R 1 1 1 1 1 1 1 1 1 Page 3 of 14 440128-001 Rev A (January 2006) This information is proprietary to Capstone® Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | SPV25 to Woodward Valve Upgrade Kit Installation – Model C60 MicroTurbine

spv25-woodward-valve-upgrade-kit-installation-–-model-c60-mi-003

PDF Search Title:

SPV25 to Woodward Valve Upgrade Kit Installation – Model C60 MicroTurbine

Original File Name Searched:

workinstr_440128-001a.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP