Text from PDF Page: 002

Heat Output Recoverable to Water* Heat Recovery* Characteristics Specification Engine exhaust temp w/o HRU** 450°F (232°C) 25 20 15 10 5°C 16 27 38 49 60 71 5.7 4.5 3.4 2.3 >350000 330000 to 350000 310000 to 330000 290000 to 270000 310000 to 290000 250000 to 270000 <250000 5° 1.1 40 F 60 80 100 120 140 160 Inlet water temperature Engine gas flow** Max water flow Max inlet water pressure Max inlet water temp 1.6 lbm/s (0.726 kg/s 30 gpm (6.8 m3/hr) 125 psig (862 kPa) 180°F (82°C) * at ISO conditions (15oC @ sea level, 60% RH) unless otherwise noted ** predicted Fuel Requirements Characteristic Input pressure Min temperature Max temp. with gas booster without gas booster* * consult sales for higher temperatures Emissions at 100% load* Characteristic NOx CO VOC * pipeline natural gas only Sound Level Characteristic Standard * Btu/hour from Heat Recovery Unit (HRU) at ISO conditions, damper fully open, ±15% Specification 4 ̋ WC to 75 psig 1 kPa to 517 kPa 35°F (1.7°C) 115°F (46°C) 150°F (66°C) Specification <5 ppmv @ 15% O2 <6 ppmv @ 15% O2 <5 ppmv @ 15% O2 Specification 78 dB(A) @ 1m Direct Exhaust Output 600 580 560 540 520 500 480 460 440 420 400 0°F 20 40 60 80 100 120 Air-inlet ambient temperature 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 Mass flow Exhaust temperature Ambient Temperature Limits Characteristic Indoor unit Outdoor unit* * some configurations may require additional cold-weather options The Microturbine Engine Cycle Specification Physical Specifications 35° to 115°F (2° to 46°C) -10° to 115°F (-23° to 46°C) Right s Front C ide Indoor unit Outdoor unit A B C (in) 71.2 42.6 87.4 (cm) 181 109 222 (in) 84.2 51.8 114.5 (cm) 214 131 291 Weight est. 4,700 lb 2,130 kg 5,000 lb 2,270 kg BA Outdoor Enclosure Minimum Clearance Requirements Characteristic Vertical clearance Indoor unit Outdoor unit Horizontal front Horizontal left and right side Horizontal rear Specification 48 in (122 cm) no overhead obstruction 48 in (122 cm) 45 in (114 cm) 36 in (91 cm) Certain Ingersoll Rand Energy Systems products were developed with the assistance of the Gas Technology Institute (formerly Gas Research Institute), Southern California Gas Company and New York Gas Group. Ingersoll Rand Energy Systems reserves the right to change or modify product design and specifications without notice. ©2006 Ingersoll-Rand Company Ingersoll Rand Energy Systems is part of the Industrial Technologies Sector of leading diversified industrial company Ingersoll Rand, a global provider of products, services and integrated solutions to industries as diverse as transportation, manufacturing, food retailing, construction, and agriculture. For more information, please visit www.ingersollrand.com. This document comprises a general overview of the products or services described herein. It is solely for informational purposes, does not represent a warranty of the information contained herein and is not to be construed as an offer to sell or a solicitation to buy. Contact Ingersoll Rand Energy Systems for detailed product, design and engineering information suitable to your specific applications. Ingersoll Rand Energy Systems reserves the right to modify its products and related product information at any time without prior notice. Energy Systems 800A Beaty Street, Davidson, North Carolina 28036 USA Phone Toll Free 1-877-477-6937 Outside USA Phone 704-896-5373 E-mail power@irco.com Website www.irenergysystems.com 120LT-060825 Exhaust temperature Inlet water flow (gpm) Mass flow (lbm/s) Inlet water flow (m3/hr)

PDF Image | MT70 Series Microturbine 70 kW Continuous Onsite Electrical Power with Integrated Heat Recovery

mt70-series-microturbine-70-kw-continuous-onsite-electrical--002

PDF Search Title:

MT70 Series Microturbine 70 kW Continuous Onsite Electrical Power with Integrated Heat Recovery

Original File Name Searched:

IR_MT70_120LT_2006.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP