The fuel gas specifications are listed in the following table. Another way to meet the battery charging requirement is to initiate a manual recharge at least 30 minutes prior (but no longer than 4 hours prior) to shutting down the MicroTurbine. This will initialize an equalization charge while the system is under load and ensure that the batteries are well charged at the onset of cooldown, even if a flameout results during cooldown. Once manually recharged, the system can be down as long as six months without battery recharging. With a manual recharge initiated, the minimum up-time is 30 minutes. Should the battery voltage dip between 175 and 200VDC, the system may not start in StandAlone mode and will need to be grid- started and run above the minimum power level (or manual recharge initiated) in order to recharge the batteries. Below 175VDC, the batteries must be recharged using an external charger. Only Capstone-trained Authorized Service Providers are authorized to charge the batteries externally. The battery pack contains high voltage and lethal quantities of energy. Failure to observe these and other safety guidelines can result in serious injury and/or death. The following table outlines the MedBtu settings and minimum power levels for various Btu content fuels. Capstone Model 330 - Medium Btu Fuel MAXIMUM FUEL GAS TEMPERATURE 50°C (122°F) MINIMUM FUEL GAS TEMPERATURE GREATER OF 0°C (32°F) or 20°C (36°F) ABOVE THE PRESSURIZED DEW POINT MINIMUM GAS LINE PRESSURE (@ MAXIMUM FUEL GAS FLOW) 34.5 kPA (5 PSIG) MAXIMUM OPERATING INLET PRESSURE (@ GUARD FILTER) FUEL GAS FLOW, MAXIMUM (@1000 BTU/SCF HHV) FUEL GAS FLOW, TYPICAL @FULL LOAD (@1000 BTU/SCF HHV) MINIMUM FUEL GAS CALORIFIC VALUE (HHV) MAXIMUM FUEL GAS CALORIFIC VALUE (HHV) 103 kPA (15 PSIG) 6.5 NM3/HR 660 SCFH 4.0 NM3/HR 660 SCFH 36,500 kJ/ NM3 950 BTU/SCF 44,180 kJ/ NM3 1150 BTU/SCF System Fuel Settings, Minimum Power Limits, and StandAlone Battery Care The MicroTurbine system’s ‘MedBtu’ setting must be adjusted according to the Btu content of the incoming fuel. Btu content determines the minimum acceptable power level for the MicroTurbine. Flameouts may occur if the minimum power level is not observed. While no system damage results from flameouts, it is essential that minimum operating times be met on systems equipped with the StandAlone option. For StandAlone systems, no greater than one week of operation below the minimum acceptable power level may elapse before the system must be run above the minimum power level for at least one hour. Failure to meet this minimum requirement may result in permanent damage to the batteries. Range Btu/scf (kCal/NM3) MedBtu setting 350-700 (40-80) ‘low’ 700-970 (80-111) ‘med’ 970-1200 (111-137) ‘normal’ Minimum Power Level 15 kW 5 kW 0 kW Initiating Manual Recharge From the display: Enter password. Select manual recharge = YES From the serial (RS232) connection: Enter password. Enter ‘BATCHG=1’ 511340/1 Application Guide - Medium Btu Fuel

PDF Image | Elevation Derating

elevation-derating-002

PDF Search Title:

Elevation Derating

Original File Name Searched:

511340 Medium Btu Fuel.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP