12000 Internal Fault BATT DC OV Battery DC Bus Overvoltage System Severity Level 5 In the Battery Controller Transient (BCT), the DC bus capacitors limit the maximum achievable DC bus voltage. To protect these components from failure, the software declares this fault condition and shuts down the system when the DC bus voltage input exceeds the DC Bus Overvoltage for any one sample. Symptom Probable Cause Analysis Repair Solution Dc Bus Voltage Input Exceeds the Dc Bus Over- voltage Limit. DC Bus Overvoltage Limit is set wrongly Check the command value and scale factor, when the RS-232 command of BCTBOV is used to set the Leg Over-current Limit. Use the right value to set the DC Bus Overvoltage Limit. The default value of the DC Bus Over- voltage Limit is wrongly set. Make sure that the BCT power board PM is programmed properly, and it is supported by the installed BCT control software. Re-program the BCT power board PM Faulty BCT control board BCT control board needs replacing. Replace BCT Control Board (See Document 513175) Faulty BCT power board BCT power board needs replacing. Replace BCT Power Board (See Document 513158) 12001 Internal Fault BATT OVER VOLT Battery Overvoltage System Severity Level 5 Batteries are very sensitive to overvoltage since they lose electrolyte through gassing if subjected to prolonged overvoltage. The software declares a battery overvoltage fault when the measured value of the battery voltage exceeds the maximum voltage value stored in the Battery Personality Module, in any control cycle. Symptom Probable Cause Analysis Repair Solution Either the Filtered Battery Voltage Exceeds the Battery Overvoltage Limit, or the Hardware Has Detected A Battery Over-voltage Condi- tion. The parameters used to detect the Battery overvoltage fault is set wrongly. Make sure that the BCT power board PM and battery pack PM are programmed properly, and they are supported by the installed BCT control software. Re-program the BCT power board PM and battery pack PM. Disconnection of the battery pack from the DPC This fault provides a protection to the Battery Controller Transient 13.8V power supply. Reboot the system to clear the fault. Faulty BCT control board BCT control board needs replacing. Replace BCT Control Board (See Document 513175) Faulty BCT power board BCT power board needs replacing. Replace BCT Power Board (See Document 513158) Observe Safety Precautions - Refer to Important Safety Instructions for Details 430001-001 Rev B (Sep 2002) 216 Troubleshooting Guide Capstone Turbine Corporation reserves the right to change or modify without notice the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | SERIES 12000 FAULT CODES Battery

series-12000-fault-codes-battery-002

PDF Search Title:

SERIES 12000 FAULT CODES Battery

Original File Name Searched:

17_430001-12000.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP