Overview SERIES 6000 FAULT CODES Operational Faults

PDF Publication Title:

Overview SERIES 6000 FAULT CODES Operational Faults ( overview-series-6000-fault-codes-operational-faults )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 012

6011 Internal Fault (Continued) Symptom Probable Cause Analysis Repair Solution Combustion ceases during Start-up (Continued) Fuel Shutoff Solenoid failed Closed Inlet pressure droops signifi- cantly on start-up indicating that fuel has been cut off. Replace Fuel Shutoff Solenoid Fuel Shutoff Solenoid failed Open May cause Hard Light Over- temperature Replace Fuel Shutoff Solenoid Fuel Manifold Solenoids failed Closed Exit pressure reading should be less than 10 psig during start. Replace Fuel Manifold Fuel Manifold Solenoid failed Open May cause Hard Light Over- temperature Replace Fuel Manifold Igniter Failure can be intermittent. Must spark continuously Replace Ignitor Fuel Inlet Pressure Sensor Reading High Compare fuel inlet pressure reading to actual fuel pressure being applied to system. Note: Systems cannot handle more pressure than the sensor is rated for. Replace Fuel Inlet Pressure Sensor. Replace Fuel Device PM. Check range on pressure transducer Replace Pressure Transducer Fuel Flow Device Feedback does not match command SPV% command does not match feedback. Replace Fuel Flow Device TET Thermocouple does not report that the Engine lit An audible engine light is heard but temperature is not reported from the controller. Replace Engine Thermo- couple. Replace Engine Harness. After replacing the engine thermocouple TET still does not increase when audible light occurs. Attempt an ECM Control Board PM upload. Replace ECM Control Board Combustion Hardware failed Fuel is being delivered with no abnormal reductions in command, but engine does not sustain combustion. Check/Replace Injectors Observe Safety Precautions - Refer to Safety Instructions for Details 430013-001 Rev A (October 2002) 94 Model C60 Troubleshooting Guide This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Overview SERIES 6000 FAULT CODES Operational Faults

PDF Search Title:

Overview SERIES 6000 FAULT CODES Operational Faults

Original File Name Searched:

11_430013_Series 6000.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)