12018 Internal Fault BATT BOARD OT Battery Board Thermistor Overtemperature System Severity Level 5 The components on the circuit board have a specific maximum temperature rating. Above this temperature the behavior of the control circuits can no longer be considered predictable. The software declares a board overtemperature fault, when the measured temperature from the board exceeds the Board Overtemperature setting, for any sample period. Symptom Probable Cause Analysis Repair Solution The Low-pass Filtered Circuit Board Tempera- ture Exceeds the Board Over- temperature Setting. The board overtempera- ture limit for the circuit board temperature sensor is commanded wrongly When use the RS-232 com- mand of BCTBOT to reset the board overtemperature limit, the value should be in °C. Use right value to set the board Over- temperature Limit. The default value of the Board overtemperature limit is set wrongly. Make sure that the BCT Power Board PM is programmed properly, and it is supported by the installed BCT control software. Re-program the BCT Power Board PM. Open/Loose Connection Check the cable connections related the vent fan of the BCT controller. Fix any loose or faulty connection. The vent fan failed or the cooling airflow is blocked. Inspect the vent fan of the BCT controller, make sure that it is working properly. Check if the cooling airflow is blocked. Fix any problem relating the vent fan and cooling airflow. Faulty BCT Control Board BCT control board needs replacing. Replace BCT Control Board (See Document 513175) 12019 Internal Fault BATT BOARD OP Battery Board Thermistor Open Failure System Severity Level 5 The software declares a Board Thermistor Open fault, when the measured board temperature is less than the Battery Controller Transient Open parameter value, for any sample period. Symptom Probable Cause Analysis Repair Solution The BCT DSP has detected the open circuit condition of the BCT Control Board thermistor. The assumed open temperature for the circuit board tempera- ture sensor is set wrongly. Make sure that the BCT Power Board PM is pro- grammed properly, and it is supported by the installed BCT control software. Re-program the BCT Power Board PM. Faulty BCT Control Board BCT control board needs replacing. Replace BCT Control Board (See Document 513175) Observe Safety Precautions - Refer to Safety Instructions for Details 430001-001 Rev D (June 2003) 13-13 Model C30 Troubleshooting Guide This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Overview SERIES 12000 FAULT CODES Battery Device Faults

PDF Search Title:

Overview SERIES 12000 FAULT CODES Battery Device Faults

Original File Name Searched:

13_12000 Faults.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)