PDF Publication Title:
Text from PDF Page: 012
12016 Internal Fault BATT HTSNK OP Battery Heat Sink Thermistor Open Failure System Severity Level 5 The software declares a Battery Heat Sink Thermistor Open fault, when the measured temperature from the heat sink is less than the Battery Controller Transient Open parameter, for any sample period. Symptom Probable Cause Analysis Repair Solution The BCT DSP Has Detected the Open Circuit Condition of the BCT Heat Sink Thermistor. The assumed open temperature for the heat sink temperature sensor is set wrongly. Make sure that the BCT Power Board PM is pro- grammed properly, and it is supported by the installed BCT control software. Re-program the BCT Power Board PM. Open/Loose Connection Check the cables and connectors related to J1 and J3 of the BCT Power Board. Tighten cable connections Faulty BCT Control Board BCT control board needs replacing. Replace BCT Control Board (See Document 513175) Faulty BCT Power Board BCT Power Board needs replacing Replace BCT Power Board (See Document 513158) 12017 Internal Fault BATT HTSNK SH Battery Heat Sink Thermistor Short Failure System Severity Level 5 The software declares a Battery Heat Sink Thermistor Short fault, when the measured temperature from the heat sink is exceeds the Battery Controller Transient Short parameter, for any sample period. Symptom Probable Cause Analysis Repair Solution The BCT DSP Has Detected the Short Circuit Condition of the BCT Heat Sink Thermistor. The assumed short temperature for the heat sink temperature sensor is set wrongly. Make sure that the BCT Power Board PM is pro- grammed properly, and it is supported by the installed BCT control software. Re-program the BCT Power Board PM. Debris or water in package. Clean the BCT controller. Check the cables and con- nectors related to J1 and J3 of the BCT Power Board. Clean the BCT Controller Faulty BCT Control Board BCT control board needs replacing. Replace BCT Control Board (See Document 513175) Faulty BCT Power Board BCT Power Board needs replacing Replace BCT Power Board (See Document 513158) Observe Safety Precautions - Refer to Safety Instructions for Details 430001-001 Rev D (June 2003) 13-12 Model C30 Troubleshooting Guide This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Overview SERIES 12000 FAULT CODES Battery Device Faults
PDF Search Title:
Overview SERIES 12000 FAULT CODES Battery Device FaultsOriginal File Name Searched:
13_12000 Faults.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)