Overview SERIES 10000 FAULT CODES Inverter Faults

PDF Publication Title:

Overview SERIES 10000 FAULT CODES Inverter Faults ( overview-series-10000-fault-codes-inverter-faults )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 016

10023 Internal Fault IDSP CNTCTR OP Inverter AC Output Contactor Failed to Open System Severity Level 4 The software declares that the contactor failed in the open position, if the contactor closed status remains low for more than the Contactor Closing Time, after the contactor drive request goes from low to high. Symptom Probable Cause Analysis Repair Solution The contactor closed status remains low for more than the Contactor Closing Time, after the con- tactor drive request went from low to high. The Contactor Closing Time is wrongly set. Make sure that the power board PM is programmed properly, and it is supported by the control soft- ware being used. Re-program the power board PM. Open/Loose Con- nection Check the connection between J21 and the AC output contactor. Tighten the cable connection. Faulty DPC Con- trol Board DPC Control Board needs replac- ing. Replace DPC Control Board Faulty DPC Power Board DPC Power Board needs replacing. Replace DPC Power Board 10024 Internal Fault IDSP CNTCTR CL Inverter AC Output Contactor Failed to Close System Severity Level 4 The software declares that the contactor failed in the closed position, if the contactor closed status remains high for more than the Contactor Opening Time, after the contactor drive request went from high to low. Symptom Probable Cause Analysis Repair Solution The contactor closed status remains high for more than the Contactor Opening Time after the con- tactor drive request went from low to high. The Contactor Opening Time is wrongly set. Make sure that the power board PM is programmed properly, and it is supported by the control soft- ware being used. Re-program the power board PM. Open/Loose Con- nection Check the connection between J21 and the AC output contactor. Tighten the cable connection. Faulty DPC Con- trol Board DPC Control Board needs replac- ing. Replace DPC Control Board Faulty DPC Power Board DPC Power Board needs replacing. Replace DPC Power Board Observe Safety Precautions - Refer to Important Safety Instructions for Details Troubleshooting Guide 168 511521-002 This information is confidential and proprietary to Capstone. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered.

PDF Image | Overview SERIES 10000 FAULT CODES Inverter Faults

PDF Search Title:

Overview SERIES 10000 FAULT CODES Inverter Faults

Original File Name Searched:

10_10000Faults.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)