10021 Internal Fault IDSP HTSK OP Inverter Heat Sink Sensor Open System Severity Level 4 The software declares a Heat Sink Sensor Open fault when the measured heat sink temperature is less than the Heat Sink Temperature Open Limit for any one sample period. Symptom Probable Cause Analysis Repair Solution The measured heat sink temperature is lower than the Assumed Ther- mistor Open Tem- perature. The Assumed Thermistor Open Temperature is wrongly set. Make sure that the power board PM is programmed properly, and it is supported by the control soft- ware being used. Re-program the power board PM. Open/Loose Con- nection. Check and clean connectors con- necting J11 and J12 of the power board, and J15 of the control board. Check related cables and make sure that they are in good condition. Clean the DPC. Faulty DPC Con- trol Board DPC Control Board needs replac- ing. Replace DPC Control Board Faulty DPC Power Board DPC Power Board needs replacing. Replace DPC Power Board 10022 Internal Fault IDSP HTSK SH Inverter Heat Sink Sensor Short System Severity Level 4 The software declares a Heat Sink Sensor Short fault when the measured heat sink temperature exceeds the Heat Sink Temperature Short Limit for any one sample period. Symptom Probable Cause Analysis Repair Solution The measured heat sink temperature is higher than the Assumed Ther- mistor Short Tem- perature. The Assumed Thermistor Short Temperature is wrongly set. Make sure that the power board PM is programmed properly, and it is supported by the control soft- ware being used. Re-program the power board PM. Debris or water in package. Check and clean connectors con- necting J11 and J12 of the power board, and J15 of the control board. Check related cables and make sure that they are in good condition. Clean the DPC. Faulty DPC Con- trol Board DPC Control Board needs replac- ing. Replace DPC Control Board Faulty DPC Power Board DPC Power Board needs replacing. Replace DPC Power Board Observe Safety Precautions - Refer to Important Safety Instructions for Details 511521-002 167 Troubleshooting Guide This information is confidential and proprietary to Capstone. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered.PDF Image | Overview SERIES 10000 FAULT CODES Inverter Faults
PDF Search Title:
Overview SERIES 10000 FAULT CODES Inverter FaultsOriginal File Name Searched:
10_10000Faults.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)