10011 Internal Fault IDSP UV A Inverter Phase A Undervoltage System Severity Level 4 10012 Internal Fault IDSP UV B Inverter Phase B Undervoltage System Severity Level 4 10013 Internal Fault IDSP UV C Inverter Phase C Undervoltage System Severity Level 4 In the Grid Connect mode, the AC undervoltage indicates that the grid is operating under some fault condition or that a local island has formed. In the Stand-alone mode, the AC undervoltage may cause the customer loads to malfunction. In either case, it is important that the inverter be shut down. The software declares an AC undervoltage fault, when any of the magnitude estimates of the phase A, B or C voltage inputs falls below [(√2) x AC Min Voltage Limit], for a period of time greater than the AC Undervoltage Time-out. Symptom Probable Cause Analysis Repair Solution Phase A, B or C voltage read- ing is lower than the AC under-voltage limit. The AC under- voltage limit is wrongly set. Make sure that the power board PM is pro- grammed properly, and it is supported by the control software being used. Re-program the frame PM or reset the limits. Debris or water in package Inspect the DPC Power Board, Control Board and the cables connecting them for any material that could short connections. Clean DPC Phase A, B or C voltage is too low. Inspect the grid voltage. If there is any transformer between the system and the grid, make sure that its wire connections are correct. Solve the problem of the grid. The neutral is not grounded prop- erly. Inspect the grounding wires. In the Grid Connect application, the neutral should not be grounded. However, the neutral must be grounded in the Stand-alone application. Correct the error in grounding. The system failed before it is syn- chronized to the grid In the Grid Connect mode, if the system failed before it is synchronized to the grid, all the following faults will be set: Over- voltage and undervoltage in all 3 phases. Overfrequency and under- frequency faults. Generally, one or more other faults will also be set, and the extra fault infor- mation gives the true reason of the failure. Solve the prob- lems indicated by the other fault codes. Faulty DPC Con- trol Board DPC Control Board needs replacing Replace DPC Con- trol Board Faulty DPC Power Board DPC Power Board needs replacing Replace DPC Power Board Observe Safety Precautions - Refer to Important Safety Instructions for Details 511521-002 161 Troubleshooting Guide This information is confidential and proprietary to Capstone. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered.PDF Image | Overview SERIES 10000 FAULT CODES Inverter Faults
PDF Search Title:
Overview SERIES 10000 FAULT CODES Inverter FaultsOriginal File Name Searched:
10_10000Faults.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP |