logo

Technical Reference Modbus Translator Module (MOXA®)

PDF Publication Title:

Technical Reference Modbus Translator Module (MOXA®) ( technical-reference-modbus-translator-module-moxa® )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 026

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Modbus Translator Module UCB Relays Relay Number (See Write register 48507 to Set) Relay Active State Battery Information Battery Enabled Battery Auto Sleep Battery Charge Battery Recharge Enable (SA only) Last Equalization Charge Date Register 40601 S Min: 1 Max: 6 N/A On Reg 48601 Update On Reg 48601 Update 2 10 5 2 30 On Reg 48707 Update On Reg 48707 Update On Reg 48707 Update On Reg 48707 Update 1 10 10 10 10 10 Mode RS232 Command Timing (Sec) Description Representation 40602 S Relay Function 0 – Standby 1 – Run 2 – Load 3 – Fault 4 – Standalone 5 – Dual Mode 6 – Disable 7 – Fuel On 8 – Purge OUTRLY(1) On Reg 48601 Update 40603 S 40701 S 40702 S 40703 S 40704 S 40705 – S 40706 40707 40708 40709 40710 40711 40712 40713 40714 40715 40716 0 – Open, 1 – Close 0 – Disabled, 1 – Enabled Units: 1 = 0.1 Hours Min: 1 = 0.1 Hours Max: 239 = 23.9 Hours 0 – Disabled, 1 – Enabled 0 – Disabled, 1 – Enabled Word 1, High Byte – Month Word 1, Low Byte – Day Word 2 - Year 1 – Sunday 2 – Monday 7 – Saturday 0 – Inactive, 1 - Active High Byte – Hour Low Byte – Minute High Byte – Hour Low Byte – Minute Units: 1 = 1 oC % Battery state of charge Integer number Units: 1 = 1 oC Units: 1 = 0.048828125 A Units: 1 = 0.048828125 Vdc OUTRLY(2) BATENA ATOSLP BATCHG RCHENA BATEQL N/A CHGEQP(1) CHGEQP(2) CHGEQP(3) BCDAT1(0)* BCDAT1(5)* BATDAT BCDAT1(2)* BCDAT1(11)* BCDAT1(12)* S Charge Permission Day (See Write register 48507 to Set) S Charge S Charge Time S Charge Time Permission Active Permission Start Permission End S Battery S Battery S Number of Equalization Temperature Base SOC Charges S,H BCT Heatsink Temperature (N3) S,H Battery Average Current (N3) S,H Battery Volts (N3) 410078 Rev A (July 2009) Page 26 of 53 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Technical Reference Modbus Translator Module (MOXA®)

technical-reference-modbus-translator-module-moxa®-026

PDF Search Title:

Technical Reference Modbus Translator Module (MOXA®)

Original File Name Searched:

410078_RevA_Modbus_Translator_Tech_Ref.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP