PDF Publication Title:
Text from PDF Page: 016
Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: ModBus Translator Module Register Mode Description Representation RS232 Command Timing (Sec) 40308 40309 40310 40401 40402 40403 40404 40405 40406 40407 40408 40409 40410 40411 40412 40413 40414 40501 40502 40503 40504 40505 – 40506 40507 40508 40509 40510 40511 40512 – 40513 S S S S S S S S S S S S S S S S S S S S S S S S S S S S Under Frequency Time (GC) Over Frequency (GC) Over Frequency Time (GC) Stand Alone Relays Output Voltage (SA) Voltage Start (SA) Voltage Ramp (SA) Under Voltage (SA) Under Voltage Time (SA) Over Voltage (SA) Over Voltage Time (SA) Output Frequency (SA) Frequency Start (SA) Frequency Ramp (SA) Under Frequency (SA) Under Frequency Time (SA) Over Frequency (SA) Over Frequency Time (SA) Load Management Settings Load Management Mode Meter Constant Utility Power Setpoint Load Following Response Time Minimum Power Shutoff Minimum Power Shutoff Time Time of Use Event (See Write register 48507 to Set) TOU Event Day TOU Event Hour TOU Event Start Command TOU Event Power Demand Units: 1 = 0.01 Seconds Units: 1 = 0.1 Hz Units: 1 = 0.01 Seconds Units: 1 = 1 VAC (line-to-line) Units: 1 = 1 VAC (line-to-line) Units: 1 = 1 VAC/s (line-to-line) Units: 1 = 1 VAC (line-to-line) Units: 1 = 0.01 Seconds Units: 1 = 1 VAC (line-to-line) Units: 1 = 0.01 Seconds Units: 1 = 0.1 Hz Units: 1 = 0.1 Hz Units: 1 = 1 Hz/s Units: 1 = 0.1 Hz Units: 1 = 0.01 Seconds Units: 1 = 0.1 Hz Units: 1 = 0.01 Seconds 0 – Disabled 2 – Load Following 3 – Time-of-Use Units: 1 = 0.001 Wh/pulse Units: 1 = 0.1 kW Units: 1 = 1 Second Units: 1 = 0.1 kW Units: 1 = 1 Minute Min: 1 Max: 20 0 – Inactive 1 – Sunday 7 – Saturday High Byte – Hour Low Byte – Minute 0–Stop,1–Start Units: 1 = 1 Watt UFRQTM OVRFRQ OFRQTM SAVOLT STVOLT STVTRT SAUVLT SAUVTM SAOVLT SAOVTM SAFREQ STFREQ STFQRT SAUFRQ SAUFTM SAOFRQ SAOFTM LMMODE LMMTRC LMUTPW LMRSPT LMMPWR LMPWTM N/A LMTOUE LMTOUE LMTOUE LMTOUE 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 On Reg 48507 Update On Reg 48507 Update On Reg 48507 Update On Reg 48507 Update On Reg 48507 Update 410040-001 Rev A (February 2003) Page 14 of 35 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Technical Reference Modbus Translator Module
PDF Search Title:
Technical Reference Modbus Translator ModuleOriginal File Name Searched:
410041_ModBus_Translator.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP |