logo

PERFORMANCE OF FUZZY LOGIC BASED MICROTURBINE GENERATION SYSTEM CONNECTED TO GRID/ISLANDED MODE

PDF Publication Title:

PERFORMANCE OF FUZZY LOGIC BASED MICROTURBINE GENERATION SYSTEM CONNECTED TO GRID/ISLANDED MODE ( performance-fuzzy-logic-based-microturbine-generation-system )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 008

0.5 0 -0.5 500 400 300 200 100 0 -100 -200 -300 -400 -500 1.5 1 0.5 0 -0.5 -1 600 400 200 0 -200 -400 -600 International Journal of Fuzzy Logic Systems (IJFLS) Vol.2, No.3, July 2012 negative in per unit, it means that, the PMSM is running as generator. To generate the turbine toque the proportional fuel demand and speed are shown in Figures 14 and 15. The inverter output voltage and load voltage are shown in Figures 16 and 17 respectively. From the Figures 16 and 17 it is observed that, the MTG system is supplying quality power to the grid. 1 x 104 0.5 0 -0.5 -1 -1.5 700 600 500 400 300 200 100 Active power in watts Reactve power in Var 1.015 1.01 1.005 1 0.995 0.99 0.985 0.98 0.975 012345678 012345678 Time (s) Figure.10 Actvie and reactive power Time(s) Figure.14 Turbine speed 0 012345678 Time(s) Time (s) Figure.11 DC link voltage Figure.15 Turbine torque -1 012345678 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 -0.1 3.2 Isolated mode 12345678 Time (s) Figure.16 Inverter voltage 1 0 -1 2.045 2.05 2.055 2.06 2.065 2.07 2.075 2.08 2.085 -1.50 1 2 3 4 5 6 7 8 Time (s) Figure.12 Turbine torque 012345678 Time(s) Time (s) Figure.17 Load voltage Figure.13 Fuel flow The fuzzy logic controlled MTG system is connected to an isolated mode and it performance is simulated for the total duration of 30sec. The variation of turbine fuel flow and torque are shown in Figure.18 and 19 respectively. From the reported Figures 18 and 19 it is observed that, the fuel demand and turbine torque increase with increase in load and decreases with decrease in load. 48 0.6 0.4 0.2 0 -0.2 -0.40 1 2 3 4 5 6 7 8 2.55 2.6 2.65 2.7 2.75 2.8 Fuel flow (p.u) Troque (p.u) DC link voltage (V) Active & reactive power Load voltage (p.u.) Inverter voltage (V) Turbine torque(p.u) Turbine speed (p.u)

PDF Image | PERFORMANCE OF FUZZY LOGIC BASED MICROTURBINE GENERATION SYSTEM CONNECTED TO GRID/ISLANDED MODE

performance-fuzzy-logic-based-microturbine-generation-system-008

PDF Search Title:

PERFORMANCE OF FUZZY LOGIC BASED MICROTURBINE GENERATION SYSTEM CONNECTED TO GRID/ISLANDED MODE

Original File Name Searched:

2312ijfls04.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP