PROCEDURES AQUATEC GROUP OF COMPANIES Capstone MicroTurbine - C65 Internal Gas Train Test Procedure SPP0001 1. Check Calibration of Woodward Pressure Gauge Method A With the turbine operational, monitor the pressure with CRMS – Record # 43 Fuel Valve Ex P (kPa) checking against the gauge on the gas regulator or a test gauge connected to an EXTERNAL gas test point. Log results for future reference. Method B With the Turbine in STAND BY and any remote start disabled. 1. Take a screen shot of ALL the turbine settings – this will be used to check that no inadvertent changes have been made. Store screen shot in a “before” tab in Excel. 2. Remove the IEC connector on the BLOCK Valve. 3. Use CRMS to energise the VENT valve by changing the USER connection bay settings, active CLOSE to active OPEN for the relay controlling the BLOCK & VENT valves. This will close the VENT VALVE. 4. Connect an air supply from the compressor to the gas test point after the BLOCK valve. 5. Note the setting of the air pressure regulator as it will have to be reset to this value after testing. VERY IMPORTANT. 6. Use CRMS to operate the two ASCO shut off valves in the open loop command box. Refer to 410015 Page 18-2. 7. Monitor the pressure with CRMS – Record # 43 Fuel Valve Ex P (kPa) checking against the gauge on the air regulator or a test gauge connected to an EXTERNAL gas test point. 8. Adjust the air pressure regulator to various set points so that a range of results can be obtained. 9. Log results for future reference. 10. De-energise the ASCO valves and replace IEC connector. 11. Return the user bay settings to the original set up. 12. Disconnect air supply from gas test point. 13. Return air regulator to the original set point as noted in Step 5. 14. Take a screen shot of ALL the turbine settings. Check these against the settings taken in Step 1. ENSURE that no inadvertent changes have been made. Store screen shot in an “after” tab in Excel. 15. Test the system for proper operation as detailed in the C65 MicroTurbine User’s Manual (400017). Aquatec-Maxcon Pty. Ltd. reserves the right to change or modify, without notice, the design, specifications, and/or Page 2 of 4 contentsofthisdocumentwithoutincurringanyobligationeitherwithrespecttoequipmentpreviouslysoldorinthe RevisionA 07-09-10 process of construction.

PDF Image | C65 Internal Gas Train Test Procedure SPP0001

c65-internal-gas-train-test-procedure-spp0001-002

PDF Search Title:

C65 Internal Gas Train Test Procedure SPP0001

Original File Name Searched:

SPP0001A_C65InternalGasTrainTestProcedure.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP