Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • U.S.A. Technical Reference: Display Panel Menu Options - Capstone MicroTurbine Display Panel Menu Hierarchy (Typical) 410045-001 Rev A (February 2004) Page 2 of 28 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction. C60 C30 Ext Aux System Data System Components Incident Log System Settings Time of Use Grid Connect Load Management Stand Alone Battery Management CHP Configuration UCB Analog Inputs UCB Output Relays Unit Data Turbine Number kW High Incident System

Incident Record <1 thru 20/20> Display Format LMTOU Event 1 thru 20/20 Stored Demand Rev Pwr Protect Voltage Auto Sleep Time CHP Installed Input Number 1 thru 3/3 Relay Number 1 thru 6/6 Turbine 1 thru 20/20 Clear Incident High Incident + Fault ECM

C60 C30 Sts Incident Text Set Date/Time

Date Time Fuel Index 1 Time

C60 C30 Current A Current B Fault Input 2 Prt Rly Test Mode Restart Delay Last OK Hour Ovrtemp Rcvry Inverter Temp Generator Temp Fuel Pressure Fuel Percentage Pwr Connect

DID DEV Fault Fuel Index 2 Command Fast Under Vltg Min TPwr Shutoff Frequency Auto Stndby Chg CHP Set Point Lower Limit Frequency Voltage A MultiPac Fuel Dev

kW RPM Btu Content Power Demand Fast Over Vltg Min TPwr Startup Under Freq Grid Batt Eq Chg CHP Feedback Upper Limit Voltage B Voltage C Turbine No. Display

Baud Rate Under Freq Over Freq Eq Charge 6-12/12 Temperature Set Point Auto Load TET °C/°F Temp 1 °C/°F Meter Const Current A Current B Start Input

Load Mgmt Fuel Assist

Voltage C Fault Input 1 Restart Delay Freq Start/Ramp First OK Hour Ovrtemp Bypass DC Voltage/ Pwr Sply Voltage TET RPM Auto Restart C60 Main Code

DPC Main Code

Current C Frequency Fault Input 2 MP Min Power CHP Control RTD C60 CHP Wtr In Tmp Battery Voltage Battery Current Engine Mode C30 Fuel Dev Code

DC Volts PS Volts Set Defaults C60 CHP Wtr Out Tmp SOC Base SOC LF Boost Pmp C30

Reboot C60 CHP Temp Fdbk Last EQ Date # EQ Charges Instald> C30 LF Prime C30 Batt Dev Legend C30 LF Man Drain C30 Voltages VA, VB, VC UCB Code

C60 CHP Dev Manuf Location Logoff Maintenance Password Required to change Battery Temp Battery kW Currents IA, IB, IC Code

Maximum Power System Demand Control Access Enter Password Modem Power C60 304 BCM

C60 C30 Batt Dev Voltage A Voltage B Fault Input 1 Over Freq Volt Start/Ramp Charge Allowed Flow Set Point Current C BCM Dev Code C60

Code

User Password No Password Required to change Emergency Stop RFC Low Time Aborted Charges Battery State Fuel Assist Code

Maint Password User Password Required to change Maximum Speed Maximum TET Charge State Charge Stage C60 C60 DPC

Display Panel Menu Hierarchy - Typical Notes: Dev = Device. DID = Device Identification. EQ = Equalization. Hz = Hertz. kW = Kilowatts. Pmp = Pump. P/N = Part Number. Sec = Seconds. S/N = Serial Number. UCB = User Connection Board. CHP = Combined Heat and Power. Screens with the C30 or C60 next to them are specific to Model C30 or Model C60 MicroTurbine respectively. All other screens are common to both MicroTurbines. 4 9 8 Temp 1 °C/°F Ambient Pressure C60 C60 1 0 6 0

PDF Image | Technical Reference Display Panel Menu Options Capstone MicroTurbine

technical-reference-display-panel-menu-options-capstone-micr-002

PDF Search Title:

Technical Reference Display Panel Menu Options Capstone MicroTurbine

Original File Name Searched:

410045_Display_Panel_Menu_Options.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP