Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Component Descriptions - Model C60 MicroTurbine Engine Control Module (ECM) The ECM is a collection of hardware/software that converts the power out of the generator into internal DC Bus voltage for controlling the power electronics, fuel system and communication throughout the system. ECM Power Board DC Bus Voltage 1. DCbusvoltagerangeinstandby 􏰪 532VDCwhenappliedgridvoltageis380VAC 􏰪 670VDCwhenappliedgridvoltageis480VAC 􏰪 288VDCwhenbatteryenabledinstandalone;nogridvoltage 2. DCbusvoltagerangeduringnormaloperation 􏰪 760VDCingridconnectmode 􏰪 750VDCto785VDCduringstandalonemode 3. ConnectsECM,LCM,andBCMPowerBoards Fusing 1. Fuses F1 and F2 are provided for protecting DC power provided to the Power Distribution Module (PDM, see below). Connections 1. Connector J1 provides scaled voltage signals to the Engine Control Board (ECB) 2. Connector J2 receives voltage inputs from the ECM Inductors 3. Connector J3 provides power to the Fan Inverter 4. Connector J4 provides DC bus power to the PDM 5. Connector J5 provides interface to the Engine IGBT Module 6. Terminal E1 is DC Bus positive 7. Terminal E2 is DC Bus negative Power Distribution Module (PDM) 1. Primary of power supply powered by DC bus 2. Power received at Connector J1 from ECM Power Board Connector J4 3. Power provided from Connector J2 to ECM Control Board Connector J8 4. Power supply activation 􏰪 ActivewhenDCbusvoltageis>250VDC 􏰪 RemainactiveuntilDCbusvoltageis<~150VDC 410035-001 Rev B (August 2003) Page 14 of 38 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Technical Reference Component Descriptions Capstone Model C60 MicroTurbine

PDF Search Title:

Technical Reference Component Descriptions Capstone Model C60 MicroTurbine

Original File Name Searched:

410035_C60_Component_Descriptions.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)