PDF Publication Title:
Text from PDF Page: 018
Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Capstone MicroTurbine Fuel Requirements Liquid Fuel Supply Conditions Requirements The liquid fuels supply conditions must be in accordance with Table 7, and as detailed in the following paragraphs. Supply Pressure Stability The supply pressure must be stable within (+/- 2%) of the nominal pressure (within the specified minimum-to-maximum pressure range) for the entire load range operation of the MicroTurbine system. Pour Point Pour Point is the lowest temperature at which a liquid will flow under specified conditions. The minimum temperature requirement (Tmin) is the lowest operational temperature for the Capstone MicroTurbine system. Based upon specific fuel properties, the minimum temperature requirement (Tmin) may be higher than the minimum supply temperature shown in Table 7. This is because it is limited by the Pour Point, Cloud point, Viscosity, or some other property listed in the applicable table. Vapor Pressure Vapor Pressure is the pressure at a given fluid temperature in which the liquid and gaseous phases of the liquid are at equilibrium. The maximum temperature (Tmax) is the highest operational temperature for the Capstone MicroTurbine system. Based upon specific fuel properties, the maximum temperature requirement (Tmax) may be lower than the maximum supply temperature shown in Table 7. This is because it is limited by the Vapor Pressure, or some other property listed in Table 11. New Fuel Acceptance Criteria Capstone evaluates three MicroTurbine system components when considering possible new fuels. These areas are identified as noted below, and as detailed in the paragraphs on the following pages. ! CombustionSystemEvaluationConcerns ! FuelSystemEvaluationConcerns ! MicroTurbine(Engine)EvaluationConcerns Additional information may be obtained from within the detail Specification ASTM D2880 (Sections X1 and X2). 410002-001 Rev A (DRAFT) Page 18 of 31 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the equipment ratings, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Technical Reference Capstone MicroTurbine Fuel Requirements
PDF Search Title:
Technical Reference Capstone MicroTurbine Fuel RequirementsOriginal File Name Searched:
410002 Fuel Rqmts TechRef_DRAFT.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)