DUAL MODE SYSTEM CONTROLLER (DMSC) USER’S MANUAL

PDF Publication Title:

DUAL MODE SYSTEM CONTROLLER (DMSC) USER’S MANUAL ( dual-mode-system-controller-dmscusers-manual )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 018

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Dual Mode System Controller (DMSC): User’s Manual Dual Mode (Grid Connect/Stand Alone) Operation Settings These settings are required to configure the DMSC and MicroTurbines to perform an automatic transition between Grid Connect and Stand Alone modes during a utility outage, and return to the Grid Connect mode as utility voltage is restored. Table 5 shows settings for Dual Mode operation. Table 5. Dual Mode Operation Settings Device / Parameter Setting Location DMSC POWER Switch DMSC MODE Switch Battery Circuit Breaker on MicroTurbines MicroTurbine Power Connection MicroTurbine Auto Restart MicroTurbine Auto Load ON AUTO ON DUAL MODE ON ON DMSC Front Panel DMSC Front Panel MicroTurbine Battery Pack MicroTurbine Display Panel/CRMS MicroTurbine Display Panel/CRMS MicroTurbine Display Panel/CRMS MicroTurbine Start Input (configured as Grid Connect and as a standby generator) GCUSER/SA REMOTE MicroTurbine Display Panel/CRMS MicroTurbine Start Input (operating as standby generator only) REMOTE MicroTurbine Display Panel/CRMS MicroTurbine UCB Solid State Relay Output (wired to DMSC terminals 9 and 10) DUAL MODE CONTROL, ACTIVE CLOSED MicroTurbine Display Panel/CRMS Disconnect Device Logic Conditions for disconnect device operation are as follows: Conditions to Close the Disconnect Device • POWER switch (S1) is in the ON or BSTART position • AND the MODE switch (S2) must be in the AUTO or GRID position • AND utility voltage is within the acceptable range of the DMSC’s UVR • AND the MicroTurbine is not in the Stand Alone Load state • AND the Annunciator Panel (if fitted) is set to Automatic Operation • AND the CPR (if fitted) is not tripped • AND the disconnect device was opened by a shunt-trip from the DMSC (not a “Remote Trip”) • AND 24V control power is available from the MicroTurbine, APS or utility powered DMSC power supply. 400023 Rev A (October 2008) Page 18 of 27 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | DUAL MODE SYSTEM CONTROLLER (DMSC) USER’S MANUAL

PDF Search Title:

DUAL MODE SYSTEM CONTROLLER (DMSC) USER’S MANUAL

Original File Name Searched:

400023A_Dual_Mode_System_Controller_UM.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)