logo

Technical Reference Grid Connect Operation – Capstone Model C30 and C65

PDF Publication Title:

Technical Reference Grid Connect Operation – Capstone Model C30 and C65 ( technical-reference-grid-connect-operation-–-capstone-model- )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 010

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Grid Connect Operation–Capstone Models C30 and C65 100 80 60 40 20 0 3 6 9 12 15 18 21 24 Time of Day (24 hours) Utility MicroTurbine Figure 2. Load Following Mode Load Following settings are configured as follows: • CRMS: From the microturbine control panel menu, select: Settings > Load Management, and then configure the desired parameters. CRMS Load Management Menu Description Value Default Activate Meter Data Acquisition Utility Pwr Setpoint Turns meter data acquisition on or off for On Load Following. Off Off 0 Allowable upper/lower utility power limits as controlled by the external power meter. -1000 to +1000 kW Response Time Required time before the system responds with a new output command based on power meter signals; Interval is used to smooth out power transients. 0 to 120 seconds 0 Min Pwr Shutoff Level Power limit below the utility setpoint (based on kW demand) that the turbine will operate before shutting down. 0to1000kW 0 Min Pwr Shutoff Time Delay The delay time that the system operates below the minimum power shutoff level, before shutting down. 0to15min 0 Power Meter Const Power Meter pulse scaling – usually preset at installation. 0 to 500.00 Wh/pulse 0.00 Min Pwr Startup Time Delay Delay time that the system operates below the minimum power shutoff level before shutting down; maximizes efficiency by limiting turbine operation at lower power levels. 0to15min 0 410027 Rev G (April 2013) Page 10 of 32 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction. kW

PDF Image | Technical Reference Grid Connect Operation – Capstone Model C30 and C65

technical-reference-grid-connect-operation-–-capstone-model--010

PDF Search Title:

Technical Reference Grid Connect Operation – Capstone Model C30 and C65

Original File Name Searched:

410027G_TR_C30-C65_GRID_CONNECT.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP