Stand Alone Operation – Capstone Model C30 and C60

PDF Publication Title:

Stand Alone Operation – Capstone Model C30 and C60 ( stand-alone-operation-–-capstone-model-c30-and-c60 )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 021

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Stand Alone Operation – Capstone Model C30 and C60 Under Frequency The system will initiate a shut down if the frequency falls below this selected value for a specified time period. Under Frequency delay is the time period allowed for the Under Frequency value to remain below the set limit. • CRMS: From the menu, select Settings > Stand Alone Voltage and Frequency Settings, and enter the desired Under Frequency value. • Display panel: Navigate as follows - Stand Alone > Under Frequency. Under Frequency Sets lower limit for operating frequency 45 – 65 Hz 59.3 for a selected time period. 0.0 – 10.00 sec 0.09 Over Frequency The system will initiate a shut down if the frequency exceeds this selected value for a specified time period. Over Frequency delay is the time period allowed for the Over Frequency value to exceed the set limit. • CRMS: From the menu, select Settings > Stand Alone Voltage and Frequency Settings, and enter the desired Over Frequency value. • Display panel: Navigate as follows - Stand Alone > Over Frequency. Over Frequency Sets upper limit for operating frequency 45 – 65 Hz 60.5 for a selected time period. 0.0 – 10.00 sec 0.09 Soft Start Frequency Soft Start Frequency establishes the starting frequency. When the output contactor closes, the system will provide demanded current at this starting frequency and immediately begin increasing the frequency up to the nominal frequency. Ramp Rate Hertz per Second establishes the rate of frequency increase. When the output contactor closes, the system will provide demanded current at the starting frequency and immediately begin increasing the output frequency at this rate. • CRMS: From the menu, select Settings > Stand Alone Voltage and Frequency Settings, and enter the desired Frequency Start and Frequency Ramp values. • Display panel: Navigate as follows - Stand Alone > Freq Start/Ramp, and enter the starting frequency and rate of frequency/sec. Stand Alone Menu Parameter Description Parameter Value Default Stand Alone Menu Parameter Description Parameter Value Default Stand Alone Menu Parameter Description Parameter Value Default Freq Start Sets start frequency and frequency rate of Ramp change to connected loads. 410028-001 Rev. C (July 2004) 0 – 60 Hz 0 – 2000 Hz 0 2000 Page 21 of 22 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Stand Alone Operation – Capstone Model C30 and C60

PDF Search Title:

Stand Alone Operation – Capstone Model C30 and C60

Original File Name Searched:

stand_alone.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)