PDF Publication Title:
Text from PDF Page: 094
Capstone CHAPTER 10 COMMUNICATIONS J12 (1) J12 (2) J12 (3) J12 (4) J12 (5) J12 (6) J12 (7) J12 (8) J12 (9) J12 (10) J12 (11) J12 (12) J12 (13) Chassis Ground SA (Stand Alone mode) GC (Grid Connect mode) Start/Stop AGND FLT1 (User Fault Input) FLT2 (User Fault Input) AGND KVAR (-) (Wattmeter) KVAR (+) (Wattmeter) PWR (-) (Wattmeter) PWR (+) (Wattmeter) AGND To be used for shield connections Dry circuit closure to AGND from (+) 5 Volt pull up, 4.7 k ohms (Note 1) Dry circuit closure to AGND from (+) 5 Volt pull up, 4.7 k ohms Dry circuit closure to AGND from (+) 5 Volt pull up, 4.7 k ohms (Note 1) Return circuit for connector J12 contact closures (Note 1) Dry circuit closure to AGND from (+) 5 Volt pull up, 4.7 k ohms (Note 1) Dry circuit closure to AGND from (+) 5 Volt pull up, 4.7 k ohms (Note 1) Return circuit for connector J12 contact closures (Note 1) Dry circuit closure to AGND from (+) 5 Volt pull up, 4.7 k ohms (Note 1) Dry circuit closure to AGND from (+) 5 Volt pull up, 4.7 k ohms (Note 1) Dry circuit closure to AGND from (+) 5 Volt pull up, 4.7 k ohms (Note 1) Dry circuit closure to AGND from (+) 5 Volt pull up, 4.7 k ohms (Note 1) Return circuit for connector J12 contact closures (Note 1) Table 10-6. Connector J12 – Contact Closure Inputs Pin Signal Parameter Note: (1) Connections made to these terminals MUST be Dry Circuit rated and isolated from ground/chassis. They may not be connected in parallel with other microturbine input terminals. Analog Inputs The C200 microturbine provides three user-configurable analog inputs at the UCB location. The function for each input can be selected independently from the following options: Not assigned Electrical Power demand These three analog inputs can be individually configured for 0-5 VDC or 4-20mA signals. The electrical signal type and the function can be set using CRMS. Refer to CRMS Technical Reference User Edition (410013) for configuring these inputs. Figure 10-3 and Figure 10-4 show example connections to the analog inputs for 4-20 mA and 0-5 VDC signal types. Note that for analog signals, the UCB provides the voltage source. Table 10-7 provides details of the analog inputs on terminal block J14. 410066 Rev C (June 2009) 10-8 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCE
PDF Search Title:
CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCEOriginal File Name Searched:
410066C_C200_Tech_Ref.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)