Text from PDF Page: 093
CHAPTER 10 Capstone COMMUNICATIONS Terminal Blocks J10 and J12 Connection Details Table 10-5 and Table 10-6 below provide additional details about the external control connections. J10 (1) J10 (2) J10 (3) J10 (4) Chassis Ground Wake-up signal if asleep (Input) Return Wake-up signal if asleep (Input) Inter Start (Input/Output) Return To be used for cable shield connections Isolated return for signal of J10 (3) Momentary (0.1 to 2 seconds) input +4 to +15 V with respect to J10 (2). Opto-isolated ( 150 VDC maximum to earth) Return for signal of J10 (5) (Note 1) +12 V JUCB Battery Power, 0.6 Amps re-settable fused (Note 2) Return for J10 (9) (Note 1) MultiPac dry circuit contact closure. Closed for normal operation, open for E-Stop. (+) 24 VDC @ N*42 milliamps (Note 1) Return for J10 (11) (Note 1) Table 10-5. Connector J10 – Miscellaneous I/O Connections Pin Signal Parameter J10 (5) Inter Start (Input/Output) (Output) = MultiPac start signal, +24 VDC, 30 milliamps/0.7 Amps maximum, momentary (0.1 to 2 seconds), 27 C200 units maximum connections. (Input) = 755 ohms load (Note 1) J10 (6) Internal Battery Wake Signal (Input) +5 V to Ground, Zin = 130 k ohms RESERVED – Do not connect external circuits. Use J10 (2) and J10 (3) for battery wake-up (Note 1) J10 (7) J10 (8) J10 (9) J10 (10) Notes: JUCB Battery Power (Output) Global E-Stop (Input) Global E-Stop (Input) Local E-Stop (Input) J10 (11) Local E-Stop (Input) Dry circuit contact closure. Closed for normal operation, open for E-Stop. (+) 24 VDC @ 42 milliamps (Note 1) (1) Connections made to these terminals MUST be Dry Circuit rated and isolated from ground/chassis. They may not be connected in parallel with other microturbine input terminals. (2) Connections made to this terminal MUST be isolated from ground/chassis. It may not be connected in parallel with other microturbine input and/or power supply terminals. 410066 Rev C (June 2009) 10-7 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCE
PDF Search Title:
CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCEOriginal File Name Searched:
410066C_C200_Tech_Ref.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)