Capstone Turbine Corporation Model C1000 User’s Manual two empty modules on the C600 and one empty module on the C800. These empty compartments can be field retrofitted with a 200 kW power module if higher system power outputs or redundancy is desired in the future. The C1000 container is suitable for outdoor installations and is of a rugged design engineered to protect the turbine assembly equipment from the elements. 2.2.8. Combined Heating and Power (CHP) Combined Heating and Power (CHP) allows the user to realize the benefits of usable electrical and thermal power from a single fuel source. The electricity provides on-site power generation, and the heat offsets or replaces local thermal loads such as space heating, pool heating and industrial process hot water. CHP requires an additional Heat Recovery Module (HRM). In addition, the oxygen-rich exhaust together with ultra-low emissions makes the direct exhaust applicable for some food processing and greenhouse uses, such as heating, cooling (by absorption), dehumidifying, baking, or drying. The HRM for use with the C600, C800 and C1000 models is an exhaust economizer with integral temperature setpoint controller and exhaust diverter. The controller provides digital readout of water temperature leaving the heat exchanger, and allows the user to set the desired outlet temperature. An electrically operated exhaust gas diverter valve is actuated by the controller to maintain outlet temperature to the selected setpoint. Power for the controller and actuator can be supplied by the auxiliary electrical output of the C1000 series turbine assembly. Contact your Capstone Authorized Service Provider for details. 2.2.9. Liquid Petroleum Gas (LPG) Option Capstone offers a C1000 series turbine assembly that enables the use of LPG fuel, which requires that all fuel piping be heat traced and insulated. The C1000 series LPG model includes insulation and heat tracing on all internal pipes. Internal heat tracing is controlled by a heat trace controller in the C1000 series enclosure. Refer to the Fuel Requirements Technical Reference (410002) for fuel definitions. 2.2.10. High Humidity Option The high humidity option enables use of the C1000 series turbine assembly in high humidity environments. The enclosure of the high humidity turbine assembly contains externally powered heaters with integral fixed temperature thermostat control. The heaters are intended to maintain the inside of the microturbine package above the ambient dew point when the microturbine is not running. The high humidity microturbine also provides increased corrosion protection by adding a protective coating (often referred to as “grease”) to points of electrical interconnection between components and cables. 2.2.11. Capstone Remote Monitoring Software Capstone Remote Monitoring Software (CRMS) is the optional Capstone proprietary software that can operate and control the turbine assembly from the user Ethernet port (see Figure 2). This allows communication interface devices (a laptop plugged in with an Ethernet cable or a remote computer via an Ethernet modem or VPN) to communicate with the C1000 series turbine assembly. 400024 Rev C (February 2013) Page 21 of 82 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Capstone Turbine Assembly C1000 Series User's Manual

capstone-turbine-assembly-c1000-series-users-manual-021

PDF Search Title:

Capstone Turbine Assembly C1000 Series User's Manual

Original File Name Searched:

400024C_UM_C1000_IND_PKG.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP