DMSC Terminal # 1 2 3 4 5 6 7 8 9 10 11 12 13 GND Common GC Enable SA Enable Start/Stop 0VDC 24 VDC Power(+) N/A N/A DMSC Active Closed A DMSC Active Closed B N/A Run Active Closed A* Run Active Closed B* Cable Shield TB3-15, 17, 19 TB3-18 TB3-20 TB3-16 TB1-4 TB1-3 N/A N/A TB1-52 TB1-53 N/A TB1-54 TB1-55 No Connection Capstone Turbine Corporation 21211 Nordhoff Street Chatsworth CA 91311 USA Technical Reference: Dual Mode System Controller (DMSC) Table 6. DMSC to C1000 Control Signal Connections Description C1000 Controller Terminal # * Used only for Annunciator Panel. DMSC to APS Connections If the DMSC is not configured with an Annunciator Panel, refer to Figure 19 for DMSC to APS connections. If the DMSC is configured with an Annunciator Panel, refer to Figure 20 for the DMSC to APS connections. Refer to Table 7 for a description of the control signals. Refer to the C1000 Technical Reference (410072) or the APS Installation Specification (480024) for more details. The wires from DMSC terminals 7 and 8 to JUCB connector J10, pins 3 and 7, comprise an optional connection necessary to enable a battery wakeup (BSTART) command from the DMSC to a MultiPac, if desired. If the first MicroTurbine in the MultiPac is a C65 or C200 model, connect the BSTART wires to the JUCB of the first MicroTurbine. If the first MicroTurbine in the MultiPac is a C1000 family (C600, C800, or C1000) model, connect the BSTART wires to the JUCB of the first power module in the C1000 series container. 410071 Rev. B (January 2009) Page 44 of 71 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | TECH REF DMSC RB
PDF Search Title:
TECH REF DMSC RBOriginal File Name Searched:
410071B_Dual_Mode_System_Controller_DMSC_TR.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)