logo

Application Guide - Model C60/C65 Dual Mode – Fast Transfer

PDF Publication Title:

Application Guide - Model C60/C65 Dual Mode – Fast Transfer ( application-guide-model-c60-c65-dual-mode-–-fast-transfer )

Next Page View | Return to Search List

Text from PDF Page: 001

Capstone Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Telephone: (818) 734-5300 • Facsimile: (818) 734-5320 • Website: www.microturbine.com Application Guide - Model C60/C65 Dual Mode – Fast Transfer Introduction Capstone MicroTurbinesTM are prime power generators, producing high quality, commercial- grade electric power in an energy dense, small footprint. Capstone MicroTurbines' clean exhaust and co-generation capabilities allow installation close to a load with complete control at the customer’s fingertips. These characteristics allow for low installed cost, quick start-up and low maintenance costs. MicroTurbines can be used to produce power with a Utility grid (Grid Connect), to work as a Stand Alone generator, or a combination of both – referred to by Capstone as “Dual Mode” functionality. Due to their design versatility, they can be applied in a variety of applications. They are currently used to provide continuous power to hotels, grocery stores, oil-field processing equipment, schools and office buildings, as well as highly-reliable off-grid power to data centers, telecom equipment and protected manufacturing processes. This Application Guide explains the performance and switching logic between Grid Connect and Stand Alone modes of operation for the Capstone C60/C65 and C60/C65 ICHP Dual Mode MicroTurbines with firmware version 4.50 or higher, which includes the ability for “Fast Transfer” between Grid Connect and Stand Alone operating modes. This document also describes operation of the Dual Mode Controller in combination with the C60/C65 to achieve Fast Transfer. Refer to the Capstone Dual Mode Controller Technical Reference 410039 (Rev D or higher), and DMC Field Re-work Instruction 440123, which documents the latest construction required for Fast Transfer. Table of Contents Introduction ....................................................................................................................1 Summary........................................................................................................................2 UL 1741 Requirements for Utility Interconnection ........................................................2 Dual Mode Functionality................................................................................................4 Grid Connect to Stand Alone Mode.........................................................................................4 Stand Alone to Grid Connect Mode.........................................................................................7 External Controller Concerns ........................................................................................8 Dual Mode Controller Functionality ...............................................................................8 MultiPac Operation with Fast Transfer........................................................................13 C60/C65 ICHP Operation with Fast Transfer .............................................................13 External Protective Relay Operation with Fast Transfer.............................................13 Related Documentation...............................................................................................14 Capstone Technical Information..................................................................................14 480011 Rev B (February 2006) Page 1 of 14 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the equipment ratings, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Application Guide - Model C60/C65 Dual Mode – Fast Transfer

application-guide-model-c60-c65-dual-mode-–-fast-transfer-001

PDF Search Title:

Application Guide - Model C60/C65 Dual Mode – Fast Transfer

Original File Name Searched:

480011_DMC_Fast_Transfer.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com | RSS | AMP