Technical Reference Display Panel Menu Options Capstone MicroTurbine

PDF Publication Title:

Technical Reference Display Panel Menu Options Capstone MicroTurbine ( technical-reference-display-panel-menu-options-capstone-micr )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 021

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • U.S.A. Technical Reference: Display Panel Menu Options - Capstone MicroTurbine Frequency Start/Ramp Frequency Ramp Start - Establishes the starting frequency for RampStart. When the output contactor closes, the system will provide demanded current at this starting frequency and immediately begin increasing the frequency at the rate established, up to the nominal frequency. Adjustable from 0 to the nominal frequency in 1-Hz increments. Default: 0 Hz. Frequency Ramp Rate - When the output contactor closes, the system will provide demanded current at the starting frequency (Freq Ramp Start) and immediately begin increasing the output frequency at this rate. Adjustable from 1 to 2000 in 1-Hz increments. Default: 2000 Hz/s. Restart Delay Restart Delay introduces a time span between an automatic restart command and the actual beginning of the restart sequence. Adjustable from 0.0 to 60.0 minutes. Default: 0.0 minute. MP Min Power (MultiPac Minimum Power) - Minimum value of total power available from the MultiPac MicroTurbines before the Master commands the MicroTurbine to go into Load State and outputting power. This setting ensures that the system has enough power generating capability before power is allowed to be exported to the load and should be set to the maximum expected load. Default: 0 kW. In Stand-alone, the Master will not transition its MultiPac MicroTurbines into the Load state until there is enough power capability to match or exceed this Minimum Power or MultiPac Power set point. - The timeout period to achieve the total power available set in above, before the system shuts down automatically (60-3600 seconds). Default: 60.0 seconds. Refer to MultiPac Operation Technical Reference (410032) as required. 410045-001 Rev A (February 2004) Page 21 of 28 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Technical Reference Display Panel Menu Options Capstone MicroTurbine

PDF Search Title:

Technical Reference Display Panel Menu Options Capstone MicroTurbine

Original File Name Searched:

410045_Display_Panel_Menu_Options.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)