Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 Service Bulletin SB0078: Model C60 v4.50 Software Release iv. For fast SA to GC transfer, the system will stay in SA operation for at least one (1) minute after detection of the grid loss. After the 1-minute delay, the system will transition from SA Load to SA Recharge state. The minimum interval between consecutive SA to GC transfers is 10 minutes. If a new request to transfer out of SA Load state is less than 10 minutes after its previous transfer request, the system will stay in SA Load until the 10-minute requirement is met. c. Functions are added to set the mode for GC reconnection. Two options are available: Automatic and Manual. The Mode setting is stored in frame PM with a default value of Manual. The (new) Fast Transfer software mode is set by using an ADMIN level RS232 command: GCEMOD = 0/1 (Automatic/Manual) ...or through the display panel (ADMIN level password is required) Grid Connect 6/13 Enable Mode 10/11 d. A time delay is added for the system to check the grid reconnection condition. The time is stored in frame PM with a default of five (5) minutes. This time delay can be set by using an ADMIN level RS232 command of: GCRDLY = time in minute ...or through the display panel (ADMIN level password is required) Grid Connect 6/13 Reconnect DLY 11/11 The allowed maximum and minimum values for the time delay are 30 minutes and five (5) minutes. e. When a system is in GC Idle Recharge state, a Start command will stop the battery recharge process. System will transfer to either Standby state or Prepare-to-Start state depending on if a user Start command is set. f. When the system is configured to run in Dual Mode operation, grid voltages must be in positive sequence. Otherwise, the system will declare “Grid Synchronization Fault (1016)” upon receiving a new user Start command. The user Start command will be set to OFF when the 7016 fault is declared. Responsibility It is the responsibility of Capstone to provide description of software changes contained within this document to Authorized Service Providers. It is the responsibility of Capstone to make available the software to Authorized Service Providers for the resolution of issues related to field MicroTurbine systems. It is the responsibility of the Authorized Service Provider to obtain the software zip files from the Members Only section of the Capstone website, and upload the software. After upload has been completed, it is the Authorized Service Provider’s responsibility to provide Capstone with a Field Service Report. 450063-001 Rev A (November 2005) Page 2 of 3 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Model C60 v4.50 Software Release

PDF Search Title:

Model C60 v4.50 Software Release

Original File Name Searched:

SB0078_C60_v4.50_Software_Release.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)