Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 Service Bulletin SB0051: Model C60 Software Version 3.91 Release Notes ♦ “3040 ECM PWRSP TMP SH" (fatal SSL) is reported when the generator power supply temperature is greater than 150 °C. 10. Broke up the “4011 SW COMPATIBILTY” software compatibility fault for specific compatibility/configuration issues. New faults for hardware incompatibilities are: ♦ “4012 ECM CONFIG” ♦ “4013 LCM CONFIG” ♦ “4014 BCM CONFIG” ♦ “4015 HEV CONFIG” - Reports a configuration fault when the BCM PM is programmed as HEV and the Frame is not and vice versa. 11. Created a new fault “12028 BATT LOW VOLT” to indicate when the battery pack voltage drops to 240 volts for 20 seconds. 12. Allows a MicroTurbine to auto-restart after a 5000 Fuel Subsystem fault with SPV PIC software version 2.14 and higher. The SPV Part Number shipped with this software is 511978-201. 13. Battery maintenance and operation improvements: ♦ Preserves the battery during Stand Alone overload conditions, by reporting a new fault “6031 OVRLOAD LOW BAT". ♦ Properly handles the battery charge command locally on MicroTurbines as well as across a MultiPac. ♦ Created a new warning level fault “6028 FAIL BAT CHARGE" to indicate that the Battery Controller is not able to transition into the Equalization Charge state after some time. ♦ Prohibits Grid Connect systems that do not have a battery from executing the GC Battery Charge logic (GC Load state recharge). ♦ Allows the user to configure the system to perform an automated Grid Connect Standby Recharge while in the GC Standby State. ♦ Prevents battery pack drainage while a MicroTurbine is in the Grid Connect Standby mode. Created a new warning level fault “6029 BATT SUBSYSTEM" which is reported when a Battery Controller fault occurs during Grid Connect operation. 14. Changed the default settings of the UCB Output Relays to be set for the new function “Unused” and configured to be “Active Open”. Notes ♦ The software zip files are located on the Members Only section of the Capstone website. ♦ Upgrades to the Troubleshooting Guide will be released soon to document the new faults created for this release. 450016-001 Rev A (February 2003) Page 2 of 3 SB0051 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Model C60 Software Verison 9.91 Release Notes
PDF Search Title:
Model C60 Software Verison 9.91 Release NotesOriginal File Name Searched:
SB0051_ModelC60SoftwareVersion391 Release Notes .pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)