Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Work Instructions: Open and OEM Enhanced Liquid Fuel System Retrofit Kit - Model C30 MicroTurbine 8 (Open Package) Install the following tubes/hoses on the FOP assembly using the listed wrenches and torque values listed below: a. Tube513143totheair-assistsolenoid(11/16-in.wrench,275in-lb) b. Tube513142totheair-assistsolenoid(11/16-in.wrench,275in-lb) c. Tube 514078 to the air-assist solenoid (7/8-in. wrench, 475 in-lb) d. Tube514077tothefuelpumpinlet(11/16-in.wrench,275in-lb) e. Tube514079tothedrainvalve(11/16-in.wrench,275in-lb) f. Hose 514726 to the fuel pump outlet (9/16-in. wrench, 135 in-lb) g. Hose509767tothedrainvalveinlet(9/16-in.wrench,135in-lb) (Open Package) The FOP assembly appears as shown when complete: 9. Check Valve to Engine PCD Tube (511866) Air Assist Outlet to Air Assist Manifold Tube (513143) Air Assist to Fuel Purge Inlet Tube (513142) From Boost Pump & Filter Outlet (514077) Fuel Pump Outlet to Fuel Manifold Inlet Hose (514726) Drain Valve Inlet to Engine Drain Elbow Hose (509767) To RFC Inlet (514078) Liquid Priming to Drain Valve Tube (513798) To Drain Tank (514079) 10.Secure the drain tank and support bracket to the frame using the retained bolt (in disassembly) and a 10 mm open-end wrench. Mounting Bolt Support Bracket 440050-001 Rev A (March 2003) Page 13 of 20 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Work Instructions Enhanced Liquid Fuel System Retrofit Kit Installation – Open and OEM Package Configurations - Model C30 MicroTurbine Systems
PDF Search Title:
Work Instructions Enhanced Liquid Fuel System Retrofit Kit Installation – Open and OEM Package Configurations - Model C30 MicroTurbine SystemsOriginal File Name Searched:
440050 Enhanced Liquid Fuel Kit Mar03.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)