Technical Reference Display Panel Menu Options Capstone MicroTurbine

PDF Publication Title:

Technical Reference Display Panel Menu Options Capstone MicroTurbine ( technical-reference-display-panel-menu-options-capstone-micr )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 020

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • U.S.A. Technical Reference: Display Panel Menu Options - Capstone MicroTurbine Frequency Frequency - Establishes the nominal output frequency. Adjustable from 45 to 65 in 1-Hz increments. Default: 60 Hz. Under Freq (Frequency Under Frequency - If the output frequency falls below this value for the time span established in , the system will shut down. Adjustable from 45 to Nominal in 0.1 Hz increments. Default: 45 Hz. Under Frequency Delay - Is the time span allowed for output frequency to fall below Under Frequency (Hz) before the system will shut down. Adjustable from 0.01 seconds to 10 seconds in 0.01 second increments. Default: 10.00 seconds. Over Freq (Frequency) Over Frequency - If the output frequency rises above this value for the time span established in Over Frequency Delay , the system will shut down. Adjustable from 65 Hz down to nominal (Frequency), in 0.1 Hz increments. Default: 65.0 Hz Over Frequency Delay - If the output frequency exceeds Over Frequency for the time span established here, the system will shut down. Adjustable from 0.01 seconds to 10 seconds in 0.01 second intervals. Default: 10.00 seconds. Volt Start/Ramp Ramp Start Voltage - Establishes the starting voltage for RampStart. When the output contactor closes, the system will provide demanded current at this starting voltage and immediately begin increasing the voltage at the rate established in Ramp Rate Volts, up to the nominal voltage (voltage is adjustable from 0 to the nominal voltage in one-volt increments. Default: 0 VAC line-to-line. Ramp Rate - Establishes the voltage increase rate for RampStart. When the output contactor closes, the system will provide demanded current at the established voltage and immediately begin increasing the voltage at this rate. Adjustable from 3 to 6000 (volts per second) in one-volt increments. Default: 3000 V/s 410045-001 Rev A (February 2004) Page 20 of 28 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Technical Reference Display Panel Menu Options Capstone MicroTurbine

PDF Search Title:

Technical Reference Display Panel Menu Options Capstone MicroTurbine

Original File Name Searched:

410045_Display_Panel_Menu_Options.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)