6007 Internal Fault ENG OVER SPEED Engine Overspeed System Severity Level 3 This Engine Overspeed fault is declared when the software reads that the engine speed is greater than 98,000 RPM. The software then commands the blow off valve to open, purging all compressed air from the engine to reduce the speed. Symptom Probable Cause Analysis Repair Solution Engine Speed Sensor Reports Reading Greater than Maximum Limit Generator Current Limit Exceeded Controls may have been incapable of extracting enough current from the generator to maintain speeds less than the maximum limit Refer to Troubleshooting for Generator Power Foldback Conditions (Fault Code 6015) Brake Resistor Tem- perature Limits Exceeded Engine is only rated to handle a full offload every five minutes. Consistent offloads can cause the brake temperature to rise and foldback on power absorption capabilities. Restart system and per- form load leveling to reduce offload require- ments. Speed Sensing Cir- cuitry Not Reading Correctly Problem occurs intermittently where the engine is operating below maximum speed (96krpm), but this fault is declared. Improper grounding can cause false speed readings Verify grounding as per installation instructions System is grounded properly, but intermittent speed-readings still occur. Replace DPC Observe Safety Precautions - Refer to Important Safety Instructions for Details 511521-002 97 Troubleshooting Guide This information is confidential and proprietary to Capstone. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered.PDF Image | SERIES 6000 FAULT CODES Operational Faults
PDF Search Title:
SERIES 6000 FAULT CODES Operational FaultsOriginal File Name Searched:
06_6000Faults.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)