6003 Internal Warning ENG PWR OVLD Engine Power Overload System Severity Level 2 Software declares an engine power overload fault when the generator power output is greater than a predetermined limit. Symptom Probable Cause Analysis Repair Solution Engine Producing Power Near Gen- erator Limit. Generator current near operating limits. This fault will trigger when the gen- erator current levels are high. The fault triggers faster than the actual protection logic. Take further action only if Fault Code 6015 is reported. Clear fault through the display panel or RS232 command. 6004 Internal Warning OUTP PWR OVRLD Output Power Overload System Severity Level 2 Software declares an output power overload fault when the inverter power output is greater than a predetermined limit. Symptom Probable Cause Analysis Repair Solution Inverter Output Pro- ducing More Power Than Controller Rat- ing. Microturbine unable to provide power required by the load for extended peri- ods of time. Look at specification and determine what load level the system is rated for. Obtain more power generation or reduce output load. Observe Safety Precautions - Refer to Important Safety Instructions for Details Troubleshooting Guide 92 511521-002 This information is confidential and proprietary to Capstone. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered.

PDF Image | SERIES 6000 FAULT CODES Operational Faults

PDF Search Title:

SERIES 6000 FAULT CODES Operational Faults

Original File Name Searched:

06_6000Faults.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)