2012 Internal Fault BRAKE FAILED Brake Failure System Severity Level 6 This fault is used to declare an error condition in the Brake Resistor IGBT module. This fault is declared if the power balance (generator power - inverter power - battery power - brake power) is greater than 37.5 kW (power imbalance factor). Symptom Probable Cause Analysis Repair Solution Brake Over- temperature Too Many Offloads Generator power output is dissipated through the brake resistor during offloads, and consecutive cycles will result in a brake overtemperature. Size loads to prevent frequent cycling Failed Brake Resistor Damage to Brake Resistor Measure resistance of brake resistor across BRK+ and chassis ground on ECM Power Board. It should be 7 Ohms (Approximately). Replace ECM Brake Resistor Observe Safety Precautions - Refer to Safety Instructions for Details 430013-001 Rev A (October 2002) 33 Model C60 Troubleshooting Guide This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | SERIES 2000 FAULT CODES Power Board Faults
PDF Search Title:
SERIES 2000 FAULT CODES Power Board FaultsOriginal File Name Searched:
07_430013_Series 2000.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)