16014 Fuel Fault LF XDUCER SH Liquid Fuel Pressure Transducer Short System Severity Level 3 This fault is reported when the liquid fuel pressure transducer reads below 0.5 psig. This fault is only detected when the liquid fuel controller has been enabled and commanded to a setpoint. Symptom Probable Cause Analysis Repair Solution Low pressure transducer fault LF Pressure Transducer failure Bad wiring or a defective Pressure Transducer can cause a short (low) reading Replace LF Pressure Transducer Harness loose or faulty Verify electrical connectivity. Harness (W122) may have been disconnected or improperly connected. Secure harness connection Check pressure harness for water or physical damage Replace harness Electric Fuel Pump Inadequate pressure provided by Electric Fuel Pump Replace Electric Fuel Pump Broken fuel line Broken fuel line could result in low pressure Replace fuel line LFC failure LFC interface circuitry could be defective Replace LFC Observe Safety Precautions - Refer to Important Safety Instructions for Details 430001-001 Rev B (Sep 2002) 242 Troubleshooting Guide Capstone Turbine Corporation reserves the right to change or modify without notice the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | SERIES 16000 FAULT CODES Liquid

PDF Search Title:

SERIES 16000 FAULT CODES Liquid

Original File Name Searched:

18_430001-16000.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)