12015 Internal Fault BATT HTSNK OT Battery Heat Sink Overtemperature System Severity Level 5 The rated power output for the Battery Intelligent Power Module (IPM) reduces as the operating temperature increases. The software declares a Battery Heat Sink Overtemperature fault when the measured heat sink temperature exceeds the Heat Sink Overtemperature parameter value, for any sample period. Symptom Probable Cause Analysis Repair Solution The low-pass filtered Heat Sink Temperature exceeds the heat sink overtempera- ture setting. The Heat Sink over- temperature limit is commanded wrongly When using the RS-232 command of BCTHOT to reset the Heat Sink overtemperature limit, the value should be in °C. Use right value to set the Heat Sink over- temperature Limit. The default value of the Heat Sink over- temperature limit is set wrongly. Make sure that the BCT power board PM is programmed properly, and it is supported by the installed BCT control software. Re-program the BCT power board PM. Debris or water in package. Clean the BCT controller. Check the cables and connectors related to J1 and J3 of the BCT power board. Clean the BCT Controller Open/Loose Connection Check the cable connections related the cooling fans. Fix any loose or Faulty connection. The Cooling fan and/or vent fan is failed or the cooling airflow is blocked. Inspect the cooling fan of the heat sink and vent fan of the BCT controller, make sure that they are working properly. Check if the cooling airflow is blocked. Fix any problem relating to the cooling fans and cooling air low. Faulty BCT Control Board BCT control board needs replacing. Replace BCT Control Board (See Document 513175) Faulty BCT Power Board BCT Power Board needs replacing Replace BCT Power Board (See Document 513158) Observe Safety Precautions - Refer to Important Safety Instructions for Details 430001-001 Rev B (Sep 2002) 224 Troubleshooting Guide Capstone Turbine Corporation reserves the right to change or modify without notice the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | SERIES 12000 FAULT CODES Battery

PDF Search Title:

SERIES 12000 FAULT CODES Battery

Original File Name Searched:

17_430001-12000.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)