PDF Publication Title:
Text from PDF Page: 006
6006 Internal Fault (Cont’d) Symptom Probable Cause Analysis Repair Solution TET rise not detected within Light Off Window Spark not provided to ignite fuel Start engine and listen for igniter to fire three times a second. WARNING: THIS IS DANGEROUS: If necessary, turn OFF power to system. Remove igniter and place it in a location where the tip will not arc with the system. Start system and verify spark is produced. Replace Igniter Check for external arcing from exciter cable to package. Replace Exciter Cable If spark is still not present after installing a new igniter, then the exciter module should be replaced. Replace Exciter Voltage not provided to Solenoids Check and verify that voltage is being provided to shutoff valves and manifold. Check/replace solenoid harness Fuel Shutoff Solenoid failed Closed Verify that the inlet pressure reading is equal to supply pressure during start (2 to 3 psig Delta P). Replace Fuel Shutoff Solenoid Fuel Shutoff Solenoid failed Open May cause Hard Light Overtemperature Replace Fuel Shutoff Solenoid Fuel Manifold Solenoid failed Closed Exit pressure reading should be less than 10 psig during start. Replace Fuel Manifold Fuel Manifold Solenoid failed Open May cause Hard Light Overtemperature Replace Fuel Manifold Fuel Inlet Pressure Sensor Reading High Compare fuel inlet pressure reading to actual fuel pressure being applied to system. Note: Systems cannot handle more pressure than the sensor is rated for. Replace Fuel Inlet Pressure Sensor. Replace Fuel Device PM. Check pressure range on pressure transducer Replace Pressure Transducer Fuel Flow Device Feedback does not match command SPV% command does not match feedback. Reload SPV PM. If problem persists, replace Fuel Flow Device. (Continued on next page) Observe Safety Precautions - Refer to Safety Instructions for Details 430013-001 Rev A (October 2002) 88 Model C60 Troubleshooting Guide This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Overview SERIES 6000 FAULT CODES Operational Faults
PDF Search Title:
Overview SERIES 6000 FAULT CODES Operational FaultsOriginal File Name Searched:
11_430013_Series 6000.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)