PDF Publication Title:
Text from PDF Page: 011
17007 CHP MTR OC BYP CHP Diverter Motor Over Current Bypass System SSL: 3 CHP SSL: FR This error detects an overcurrent in the linear actuator motor during operation. If at any time an overcurrent condition occurs while moving towards the Bypass direction, the 17007 fault is declared which will cause the MicroTurbine to shut down. Symptom Probable Cause Analysis Repair Solution Water temperature high. MicroTurbine shuts down Linear actuator cable Remove HRM panel to inspect linkage and linear actuator. Inspect linear actuator cable for short or open fault. Fix cable problem. Linear actuator failure 1. Inspect linkage to see if there is anything interfering with the actuator diverter linkage movement. If Yes, go to 2. If No, go to 3. 2. Remove foreign object and restart the unit. If the fault clears, the problem is solved (observe linkage movement during self-test to see if linkage is intact). If the fault does not clear, go to 5. (Replace linkage xxx because it is damaged.) 3. Disconnect actuator from linkage by removing the fastener on the extended end. 4. Start the unit ensuring the linear actuator can travel its full length without interference. Does the unit pass the self- test? If Yes, go to 5. If No, go to 12 (Replace linear actuator). Linkage/Diverter failure 5. Move the bell crank assembly back and forth in the mid- range of diverter travel and feel for any binding in linkage. If binding exists, go to 7. If binding does not exist, go to 6. 6. Rotate actuator on pivot in actuator cradle to check for binding. If binding exists, go to 12 (Cradle could be faulty as well). If binding does not exist, go to 7. 7. Disconnect push-rod assembly from diverter link and bell crank - Press push-rod assembly on ground, compressing the springs to see if compression is smooth (the compression motion should be smooth without sticking or friction). If sticking or friction exists, go to 11. If there is no sticking or friction, go to 8. 8. Push diverter link through entire travel path pressing diverter link to each end stop. If it reaches end stop without excessive force (greater than 40 lbs), go to 9. If it reaches end stop with excessive force, go to 10. Continued on next page Observe Safety Precautions - Refer to Safety Instructions for Details 430013-001 Rev C (July 2003) 14-11 Model C60 Troubleshooting Guide This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Overview SERIES 17000 FAULT CODES Integrated CHP Faults
PDF Search Title:
Overview SERIES 17000 FAULT CODES Integrated CHP FaultsOriginal File Name Searched:
14_17000 Faults.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)