Overview SERIES 10000 FAULT CODES Inverter Faults

PDF Publication Title:

Overview SERIES 10000 FAULT CODES Inverter Faults ( overview-series-10000-fault-codes-inverter-faults )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 008

10008 Internal Fault IDSP OV A Inverter Phase A Overvoltage System Severity Level 4 In the Grid Connect mode, the AC overvoltage indicates that the grid is operating under some fault condition or that a local island has formed. In the Stand-alone mode, the AC overvoltage may damage the customer load. In either case, it is important that the inverter be shut down. The software declares an AC overvoltage fault, when any of the magnitude estimates of the phase A, B or C voltage inputs exceeds [(√2) x AC Max Voltage Limit], for a period of time greater than the AC Overvoltage Time-out. 10009 Internal Fault Inverter Phase B Overvoltage System Severity Level 4 10010 Internal Fault IDSP OV B IDSP OV C Inverter Phase C Overvoltage System Severity Level 4 Symptom Probable Cause Analysis Repair Solution Phase A, B or C voltage read- ing is higher than the AC over-voltage limit. The AC overvoltage limit is wrongly set. Make sure that the power board Person- ality Module (PM) is programmed prop- erly, and it is supported by the control software being used. Re-program the frame PM or reset the limits. Open/Loose Con- nection Check the connection of the cable that connects to the port J15 of the DPC Con- trol Board. Tighten cable con- nections Phase A, B or C volt- age is too high. Inspect the grid voltage. If there is any transformer between the system and the grid, make sure that its wire connections are correct. Solve the problem of the grid. The neutral is not grounded properly. Inspect the grounding wires. In the Grid Connect application, the neutral should not be grounded. However, the neutral must be grounded in the Stand-alone application. Correct the error in grounding. The system failed before it is synchro- nized to the grid In the Grid Connect mode, if the system failed before it is synchronized to the grid, all of the following faults will be set: Overvoltage and undervoltage in all 3 phases. Overfrequency and under- fre- quency faults. Generally, one or more other faults will also be set, and the extra fault information gives the true reason of the failure. Solve the prob- lems indicated by the other fault codes. Faulty DPC Control Board DPC Control Board needs replacing Replace DPC Con- trol Board Faulty DPC Power Board DPC Power Board needs replacing. Replace DPC Power Board Observe Safety Precautions - Refer to Important Safety Instructions for Details Troubleshooting Guide 160 511521-002 This information is confidential and proprietary to Capstone. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered.

PDF Image | Overview SERIES 10000 FAULT CODES Inverter Faults

PDF Search Title:

Overview SERIES 10000 FAULT CODES Inverter Faults

Original File Name Searched:

10_10000Faults.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)