5012 Internal Fault FRM EEPROM CSUM Frame EEPROM Checksum System Severity Level 7 A fault is declared when the checksum calculation used to verify the data stored in the Frame EEPROM personality module is not correct. Symptom Probable Cause Analysis Repair Solution CRC of Frame Data Struc- tures Can Not Be Verified. Water in Engine Har- ness In humid environments temperatures near the microturbine can reach the dew point. Water in the back of the connector will short the communica- tion bus wires. Dry Engine Harness Loose Harness Con- nection Connections can come loose through handling of device or during compo- nent changing. Secure Engine Harness Connection to Main Controller and Frame Personality Module. Data Has Become Corrupted Data structures may have become corrupted during operation. Reprogram Frame EEPROM data struc- tures. Frame EEPROM Device Has Failed Device has intermittent problem that causes data errors when reading. Replace Frame Person- ality Module Engine Harness Failed Problem persists even when PM is replaced with programmed module. Replace Engine Har- ness Communication Driver Chip If multiple EEPROM faults are reported in system, then the problem must reside in the communication driver. Replace DPC Control Board Observe Safety Precautions - Refer to Important Safety Instructions for Details 511521-002 85 Troubleshooting Guide This information is confidential and proprietary to Capstone. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered.

PDF Image | Capstone SERIES 5000 FAULT CODES

PDF Search Title:

Capstone SERIES 5000 FAULT CODES

Original File Name Searched:

05_5000Faults.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)