PDF Publication Title:
Text from PDF Page: 059
Capstone Turbine Corporation 21211 Nordhoff Street Chatsworth CA 91311 USA CRMS (User Edition – Chapter 11: MicroTurbine Data Windows) Table 11-1. Descriptions for MicroTurbine Data 1 and Data 2 Windows No. Parameter (Units) Description 1 Control Date 2 Control Time 3 Engine Speed (rpm) 4 Turbine Exit Temp (F) 5 Compressor In Temp (F) 6 Ambient Pressure (psia) 7 Incident Record 8 Starts 9 Hours 10 System Severity Level 11 System State 12 Power Enable 13 Power Demand (W) 14 Power Supply Voltage (V) 15 Start Command (0/1) 16 Fuel Inlet P LP (psig) 18 Fuel Inlet P HP (psig) 19 Fuel Valve Ex P (psig) 20 Bat Therm. Temp (F) 21 Bat SOC (%) 22 Bat Volts (Vdc) 23 BC DC Bus (V) 24 Inv DC Bus Volts (Vdc) 410013 Rev H (December 2008) Current date set in the MicroTurbine used in the Incident History and for the day of week calculations used for Time of Use operation. Value displayed in mm/dd/yyyy. Current time set in the MicroTurbine used for time information in the Incident History and for Time of Use operation. Value displayed in hh:mm:ss. Current operating speed of the MicroTurbine in revolutions per minute (rpm). Current average of the two TET thermocouple indications (F or C). Current measurement of the compressor inlet thermistor used to measure the air temperature at the inlet of the compressor wheel in the MicroTurbine generator (F or C). Measurement of the ambient pressure (psia or kPa). A default value of 14.696 is used if Ambient Pressure failed faults are present. Current incident in the system with the highest system severity level. Equates to the number of successful bearing starts or engine rotations above zero rpm. This value is used for warranty starts. Number of operating hours of the system above zero rpm. This value is used for warranty time. Highest system severity level of any incident currently reported by the system. Current operating system state of the software controls. Value is 1 in Stand Alone mode if the output contactor is closed and actively producing power to the connected loads. Current power demand in the Grid Connect mode in Watts (W). Current value of the internal power supply voltage in Volts (V). Value is 1 if a start command is currently issued to the system. Value is zero if a stop command has been issued. Current inlet pressure on a low-pressure fuel system as reported by the RFC (psig or kPa). Current inlet pressure as read from the SPV (psig or kPa). Current downstream pressure indication as reported by the fuel valve in psig (or kPa). Current temperature of the battery pack thermistor (F or C). Indicates first battery pack in Model C200. Calculated state of charge (SOC) of the battery pack. Value displayed in percent (%). Indicates first battery pack in Model C200. Calculated voltage of the battery pack in Volts DC (Vdc). Indicates first battery pack in Model C200. Internal DC Bus voltage of the Battery Controller power board in Volts DC (V). Indicates first battery controller in Model C200. Current DC Bus voltage of the power board in Volts DC (Vdc). Page 11-4 17 Fuel Outlet P LP (psig) Current downstream pressure indication on a low-pressure fuel system as reported by the RFC (psig or kPa). This value is the same as that for the Fuel Inlet P HP parameter on a Low Pressure Foil Bearing RFC MicroTurbine. Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Technical Reference Capstone Remote Monitoring System (User Edition)
PDF Search Title:
Technical Reference Capstone Remote Monitoring System (User Edition)Original File Name Searched:
410013H_CRMS_User_Edition_TR.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)