PDF Publication Title:
Text from PDF Page: 015
19XR DIMENSIONS (MARINE WATERBOX) ft-in. NA NA 12- 51/2 14- 9 16- 51/2 15- 23/4 16-113/4 15- 31/2 15- 31/2 17- 0 17- 0 15- 41/8 17- 05/8 18- 35/8 20- 35/8 18- 4 20- 4 2-Pass* A (Length, Marine Waterbox) mm NA NA 3797 4496 5017 4642 5163 4661 4661 5182 5182 4677 5197 5579 6188 5583 6198 1 or 3-Pass† ft-in. NA NA 14- 11/4 16- 43/4 18- 11/4 16- 31/4 18- 43/4 16- 81/2 16- 81/2 18- 5 18- 5 16- 83/4 18- 51/4 19- 93/4 21- 93/4 19-101/2 21-101/2 mm NA NA 4299 4997 5518 5086 5607 5093 5093 5613 5613 5099 5620 6039 6648 6058 6668 ft-in. NA NA 6- 11/16 6- 11/16 6- 11/16 6- 31/4 6- 31/4 6- 87/8 6- 87/8 6- 87/8 6- 87/8 6-113/4 6-113/4 8- 81/8 8- 81/8 9- 55/8 9- 55/8 HEAT EXCHANGER SIZE B WIDTH mm 10to12 NA 15to17 NA 20to22 1856 30to32 1856 35to37 1856 40to42 1911 45to47 1911 50to52 2054 5A to 5C 2054 55 to 57 2054 5F to 5H 2054 60to62 2127 65to67 2127 70to72 2645 75to77 2645 80to82 2886 85to87 2886 *Assumes both cooler and condenser nozzles on same end of chiller. †1 or 3-pass length applies if cooler is a 1 or 3-pass design. NOTES: 1. Service access should be provided per American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) 15, latest edition, National Fire Protection Association (NFPA) 70, and local safety code. 2. Allowatleast3ft(915mm)overheadclearanceforserviceriggingforframe2-4compressor.Overheadclearanceforservicerig- ging frame 5 compressor should be 5 ft (1524 mm). 3. Dimensions are approximate. Certified drawings available upon request. 4. Marine waterboxes may add 6 in., to the width of the machine. See certified drawings for details. 5. ‘A’ length dimensions shown are for standard 150 psi design and victaulic connections. The 300 psi design and/or flanges will add length. See certified drawings. 6. 19XRV height — check certified drawings. 7. Not all waterbox/pass combinations are available with unit-mounted VFD. Check selection program for availability. FRAME SIZE NOZZLE SIZE NOZZLE SIZE (in.) (Nominal Pipe Size) 1-Pass 10 10 10 10 10 14 14 8 Cooler 2-Pass 10 12 14 6 8 8 8 8 3-Pass 10 12 6 6 6 6 6 8 1-Pass 10 10 10 10 10 14 14 8 2-Pass 10 10 12 14 6 8 8 8 Condenser 3-Pass 16 26 36 46 58 68 7 12 8 12 15PDF Image | Carrier Product Data 19XR,XRV High-Efficiency Hermetic Centrifugal Liquid Chiller 50/60 Hz HFC-134a 19XR — 200 to 1500 Nominal Tons (703 to 5275 kW) 19XRV — 200 to 800 Nominal Tons (703 to 2813 kW)
PDF Search Title:
Carrier Product Data 19XR,XRV High-Efficiency Hermetic Centrifugal Liquid Chiller 50/60 Hz HFC-134a 19XR — 200 to 1500 Nominal Tons (703 to 5275 kW) 19XRV — 200 to 800 Nominal Tons (703 to 2813 kW)Original File Name Searched:
19XRdata.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)